Skip to main content
Omron 61F-GP-NH AC120 — General Purpose Relays

Omron 61F-GP-NH AC120 Level Controller, 120VAC, SPDT Relay

MPN61F-GP-NH AC120
Active

Omron 61F Series, High/Low Level Controller, 120VAC supply, SPDT (2 Form C) relay output, Socketable, Plug In 11-pin octal, Sensitivity 10kOhm ~ 40kOhm, 50m max sensor distance.

StockContact for availability
Lead timeIn Stock wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

61F-GP-NH AC120 — Identification
ParameterValue
Series61F

Contacts & Switching

61F-GP-NH AC120 — Contacts & Switching
ParameterValue
Contact formSPDT (2 Form C)
Contact rating at voltage3A @ 250VAC

Coil & Supply

61F-GP-NH AC120 — Coil & Supply
ParameterValue
Supply voltage range120VAC

Function & Indication

61F-GP-NH AC120 — Function & Indication
ParameterValue
TypeHigh/Low Level

Mechanical

61F-GP-NH AC120 — Mechanical
ParameterValue
Mounting typeSocketable
Termination stylePlug In, 11 Pin (Octal)

Environmental

61F-GP-NH AC120 — Environmental
ParameterValue
Operating temperature range-10°C ~ 55°C

Other specifications

61F-GP-NH AC120 — Other specifications
ParameterValue
Weight0.342 lb (155.13 g)
Output signalRelay
Sensitivity10kOhm ~ 40kOhm
Distance - control to sensor50m

Product details

The Omron 61F-GP-NH AC120 is a High/Low Level controller from the 61F series, running on a 120VAC supply. Its SPDT (2 Form C) relay output switches loads up to 3A at 250VAC, which is enough for direct control of a small pump or valve pilot — no intermediate relay needed for most tank-level circuits.

Sensitivity and sensing range

The sensitivity adjustment covers 10kOhm to 40kOhm, letting you tune the detection threshold for the conductivity of the liquid — lower resistance for conductive fluids like water, higher for less conductive media. The controller can be placed up to 50m from the electrode sensor, which gives you flexibility in panel location relative to the tank.

Socketable design with an 11-pin octal plug-in base. The termination style means it drops into a standard octal relay socket — common across panel builds — so swapping a failed unit takes seconds without disturbing the wiring.

Listed as Active in production status. This is a mature, broadly stocked part in the 61F family — a fast mover for tank-level control across water treatment, process, and packaging lines.

Frequently asked questions

Where can I buy 61F-GP-NH AC120 and get current pricing?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time.

What is the sensitivity range of the 61F-GP-NH AC120?

The sensitivity adjustment covers 10kOhm to 40kOhm, allowing tuning for different liquid conductivities.

What type of output does the 61F-GP-NH AC120 have?

It has an SPDT (2 Form C) relay output rated at 3A at 250VAC.

How far can the sensor be from the 61F-GP-NH AC120 controller?

The maximum distance from the controller to the electrode sensor is 50m.

MPN
61F-GP-NH AC120