Omron 61F series, High/Low Level liquid level controller, 100VAC supply, relay output, SPST-NO + SPDT contacts, 0~2kOhm sensitivity, socketable 11-pin octal.

$319.74 – $329.29Ref. price · indicative, final on quote
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

61F-GP-NR-AC100 — Identification
ParameterValue
Series61F
61F-GP-NR-AC100 — Contacts & Switching
ParameterValue
Contact formSPST-NO (1 Form A), SPDT (1 Form C)
Contact rating at voltage3A @ 250VAC
61F-GP-NR-AC100 — Coil & Supply
ParameterValue
Supply voltage range100VAC
61F-GP-NR-AC100 — Function & Indication
ParameterValue
TypeHigh/Low Level
61F-GP-NR-AC100 — Mechanical
ParameterValue
Mounting typeSocketable
Termination stylePlug In, 11 Pin (Octal)
61F-GP-NR-AC100 — Environmental
ParameterValue
Operating temperature range-10°C ~ 55°C
61F-GP-NR-AC100 — Other specifications
ParameterValue
Weight0.342 lb (155.13 g)
FeaturesTwo Wire/Three Probe
Output signalRelay
Sensitivity0 ~ 2kOhm
Distance - control to sensor800m

Product details

The Omron 61F-GP-NR-AC100 is a High/Low Level liquid level controller from the 61F series, running on a 100VAC supply. It uses a two-wire or three-probe sensing arrangement with a sensitivity range of 0 to 2 kOhm, making it suitable for conductive liquids in tanks or reservoirs where you need both high and low level detection. Output is via a relay with a contact configuration of SPST-NO (1 Form A) and SPDT (1 Form C), rated at 3A at 250VAC. The control-to-sensor distance can extend up to 800 meters, which gives flexibility for remote tank monitoring.

Socketable with an 11-pin octal base — mates to a standard relay socket, so panel wiring is straightforward. Termination style is plug-in, meaning you can swap the controller without disturbing the field wiring.

Frequently asked questions

Where can I buy 61F-GP-NR-AC100 and get a price?

This part is sourced and quoted to order against an RFQ through independent distribution. Submit an RFQ for current availability and pricing.

What is the supply voltage for 61F-GP-NR-AC100?

The supply voltage is 100VAC.

What is the sensitivity range of this level controller?

The sensitivity is adjustable from 0 to 2 kOhm, which determines the conductivity threshold for detecting liquid presence.

MPN
61F-GP-NR-AC100