Skip to main content
Omron 61F-GP-NT AC120 — General Purpose Relays

Omron 61F-GP-NT AC120 Level Controller, 120VAC, 0-4kOhm

MPN61F-GP-NT AC120
Active

Omron 61F Series, High/Low Level Controller, 61F-GP-NT AC120, 120VAC supply, 0 ~ 4kOhm sensitivity, SPDT relay output, Socketable, Plug In 8 Pin (Octal) termination.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

61F-GP-NT AC120 — Identification
ParameterValue
Series61F
61F-GP-NT AC120 — Contacts & Switching
ParameterValue
Contact formSPDT (2 Form C)
Contact rating at voltage3A @ 250VAC
61F-GP-NT AC120 — Coil & Supply
ParameterValue
Supply voltage range120VAC
61F-GP-NT AC120 — Function & Indication
ParameterValue
TypeHigh/Low Level
61F-GP-NT AC120 — Mechanical
ParameterValue
Mounting typeSocketable
Termination stylePlug In, 8 Pin (Octal)
61F-GP-NT AC120 — Environmental
ParameterValue
Operating temperature range-10°C~55°C
61F-GP-NT AC120 — Other specifications
ParameterValue
Weight0.342 lb (155.13 g)
Output signalRelay
Sensitivity0 ~ 4kOhm
Distance - control to sensor600m

Product details

The Omron 61F-GP-NT AC120 is a High/Low Level controller from the 61F series, designed to detect and control liquid levels via electrode probes. It operates on a 120VAC supply and switches a SPDT relay (2 Form C) rated at 3A at 250VAC. The sensitivity range of 0 to 4kOhm covers most conductive liquids — water, weak acids, coolants — where the resistance between probes drops below the set threshold.

The 0 to 4kOhm sensitivity range is the core selection parameter. Set it to the actual resistance of your liquid at operating temperature — clean water is roughly 10-50 kOhm per cm, so this controller works with a probe spacing that keeps the loop resistance under 4 kOhm. The 600m maximum distance between controller and sensor means the electrode head can be placed far from the panel, useful for deep tanks or remote sumps. The SPDT relay output (2 Form C) at 3A/250VAC drives a small pump contactor or alarm directly. If your load exceeds 3A, interpose a power relay. The socketable octal base (8-pin plug-in) makes replacement a 30-second swap — no rewiring, which matters when a sump pump controller fails at 2 AM.

The 61F-GP-NT AC120 mounts via its octal socket to a DIN rail or panel. The 8-pin plug-in termination matches standard relay sockets (e.g. Omron PYF-08A or equivalent).

Frequently asked questions

What is the closest pin-compatible alternative to 61F-GP-NT AC120 in this family?

Within the 61F series, the 61F-GP-NT-AC120 shares the same octal base and sensitivity range with the 61F-GP-N8-AC120. The difference is the contact form: the -N8 variant uses a different relay configuration. Verify your control circuit's contact arrangement before substituting.

What is the 61F-GP-NT AC120's listed type?

It is a High/Low Level controller, meaning it detects both high and low liquid levels and can be wired for fill or drain logic.

How do I get current pricing and availability for 61F-GP-NT AC120?

Submit an RFQ through this listing. Pricing and stock are confirmed at quote time through our independent distribution network.

MPN