Skip to main content
Omron 61F-GPN-V50-AC120 — General Purpose Relays

Omron 61F-GPN-V50-AC120 Leak Detection, 120VAC, 0-50kOhm

MPN61F-GPN-V50-AC120
Active

Omron 61F series, Leak Detection controller, 120VAC, adjustable sensitivity 0 ~ 50kOhm, SPDT (2 Form C) relay output, plug-in 11-pin octal base.

$467.68 – $996.95Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

61F-GPN-V50-AC120 — Identification
ParameterValue
Series61F
61F-GPN-V50-AC120 — Contacts & Switching
ParameterValue
Contact formSPDT (2 Form C)
Contact rating at voltage3A @ 250VAC
61F-GPN-V50-AC120 — Coil & Supply
ParameterValue
Supply voltage range120VAC
61F-GPN-V50-AC120 — Function & Indication
ParameterValue
TypeLeak Detection
61F-GPN-V50-AC120 — Mechanical
ParameterValue
Mounting typeSocketable
Termination stylePlug In, 11 Pin (Octal)
61F-GPN-V50-AC120 — Environmental
ParameterValue
Operating temperature range-10°C ~ 50°C
61F-GPN-V50-AC120 — Other specifications
ParameterValue
FeaturesAdjustable Sensitivity
Output signalRelay
Sensitivity0 ~ 50kOhm

Product details

The Omron 61F-GPN-V50-AC120 is a leak detection controller from the 61F series, designed to sense conductive liquid presence or absence via a probe circuit. It operates on a 120VAC supply and provides a SPDT (2 Form C) relay output rated at 3A at 250VAC.

Sensitivity and Adjustment

The adjustable sensitivity range of 0 to 50 kOhm lets you tune the detection threshold for the conductivity of the target liquid — set it low for clean water, higher for oils or deionized fluids. This is set via a potentiometer on the unit, so you can dial it in on the bench or in the panel without swapping resistors.

Mounting and Termination

Socketable mounting with an 11-pin octal plug-in base means the controller swaps in seconds without rewiring — pull the old one, plug the spare. The termination style is plug-in, 11 pin (octal), matching standard octal relay sockets found in most control panels.

Listed as active in production. For a critical spare on a legacy tank-farm or sump-pump panel, one in the cabinet saves a downtime event.

Frequently asked questions

What is 61F-GPN-V50-AC120 used for?

It is a leak detection controller used to detect the presence or absence of conductive liquids — typically water, coolant, or chemical solutions — in tanks, sumps, or pipelines.

Where can I buy 61F-GPN-V50-AC120?

This part is sourced and quoted to order through independent distribution. Submit an RFQ for current pricing and availability.

What is the sensitivity range of 61F-GPN-V50-AC120?

The adjustable sensitivity covers 0 to 50 kOhm, letting you match the probe circuit to the conductivity of the target liquid.