Skip to main content
Omron 61F-GPN-V50 AC240 — General Purpose Relays

Omron 61F-GPN-V50 AC240 Leak Detection Relay, 0~50kΩ Sensiti

MPN61F-GPN-V50 AC240
Active

Omron 61F series, Leak Detection Relay, SPDT (2 Form C), Adjustable 0 ~ 50kOhm Sensitivity, 240VAC Supply, Plug In 11-Pin Octal, 3A @ 250VAC.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

61F-GPN-V50 AC240 — Identification
ParameterValue
Series61F
61F-GPN-V50 AC240 — Contacts & Switching
ParameterValue
Contact formSPDT (2 Form C)
Contact rating at voltage3A @ 250VAC
61F-GPN-V50 AC240 — Coil & Supply
ParameterValue
Supply voltage range240VAC
61F-GPN-V50 AC240 — Function & Indication
ParameterValue
TypeLeak Detection
61F-GPN-V50 AC240 — Mechanical
ParameterValue
Mounting typeSocketable
Termination stylePlug In, 11 Pin (Octal)
61F-GPN-V50 AC240 — Environmental
ParameterValue
Operating temperature range-10°C~50°C
61F-GPN-V50 AC240 — Other specifications
ParameterValue
FeaturesAdjustable Sensitivity
Output signalRelay
Sensitivity0 ~ 50kOhm

Product details

The Omron 61F-GPN-V50 AC240 is a socket-mounted leak detection relay from the 61F series, designed to sense conductive liquid presence or absence through an adjustable probe circuit. It operates on a 240VAC supply and provides a SPDT relay output rated for 3A at 250VAC — enough to drive a small pump, alarm horn, or PLC input directly. Sensitivity is adjustable from 0 to 50 kΩ via an onboard potentiometer, which lets you tune the detection threshold for different liquid conductivities — from deionized water (high resistance) to conductive process fluids (low resistance). This is the main tuning parameter on installation; set it too sensitive and you get false trips on condensation, too insensitive and it misses a leak.

Frequently asked questions

What is the sensitivity range of the 61F-GPN-V50 AC240?

Sensitivity is adjustable from 0 to 50 kΩ, allowing the relay to detect leaks in fluids with varying conductivity — from nearly deionized water to conductive process liquids.

What is the closest pin-compatible alternative to the 61F-GPN-V50 AC240?

The 61F-GPN-V50 AC240 is a specific variant with a 0–50 kΩ adjustable sensitivity range and 240VAC supply. Other 61F-GP variants share the same 11-pin octal socket and SPDT relay output but differ in fixed sensitivity values (e.g., 0–10 kΩ or 0–100 kΩ) or supply voltage (e.g., 24VAC/VDC). The pinout is consistent across the 61F-GP family, so swapping between them requires only a sensitivity re-check at commissioning.

Where can I buy the 61F-GPN-V50 AC240?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm offer.

MPN
61F-GPN-V50 AC240