Skip to main content
Omron 61F-HSL AC110 — General Purpose Relays

Omron 61F-HSL AC110 Level Controller, 110VAC, Adjustable Sen

MPN61F-HSL AC110
Active

Omron 61F Series, High/Low Level Controller, SPDT (2 Form C) Relay Output, 110VAC Supply, Adjustable Sensitivity 0 ~ 5MOhm, Socketable, Plug In 8 Pin (Octal).

$386.55 – $594.69Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

61F-HSL AC110 — Identification
ParameterValue
Series61F
61F-HSL AC110 — Contacts & Switching
ParameterValue
Contact formSPDT (2 Form C)
Contact rating at voltage5A @ 220VAC
61F-HSL AC110 — Coil & Supply
ParameterValue
Supply voltage range110VAC
61F-HSL AC110 — Function & Indication
ParameterValue
TypeHigh/Low Level
61F-HSL AC110 — Mechanical
ParameterValue
Mounting typeSocketable
Termination stylePlug In, 8 Pin (Octal)
61F-HSL AC110 — Environmental
ParameterValue
Operating temperature range-10°C ~ 55°C
61F-HSL AC110 — Other specifications
ParameterValue
Weight0.531 lb (240.86 g)
FeaturesAdjustable Sensitivity
Output signalRelay
Sensitivity0 ~ 5MOhm

Product details

The Omron 61F-HSL AC110 is a High/Low Level controller from the 61F series, designed for tank fill-and-drain logic with a single relay output. It operates on 110VAC supply and provides SPDT (2 Form C) contacts rated at 5A @ 220VAC — enough to drive a small pump contactor or solenoid valve directly. The adjustable sensitivity range of 0 ~ 5MOhm means it can detect anything from tap water (low resistance) to demineralized water or certain chemicals (high resistance), making it a flexible fit for process tanks, sumps, and cooling towers.

The High/Low Level type gives you two setpoints from one controller: a high-level stop and a low-level start (or reverse, depending on wiring). That's the standard pump-down or pump-up sequence — no separate low-level relay needed. The SPDT (2 Form C) output provides both normally-open and normally-closed contacts, so you can wire fail-safe logic (pump off on fault) without an extra interposing relay. Sensitivity adjustment from 0 to 5MOhm covers most conductive liquids. At the low end (0 ohms), it triggers on any conductive path; at 5MOhm, it can detect high-resistivity fluids like deionized water or certain alcohols. If you're switching between product runs with different liquid types, you dial the sensitivity per batch — no probe swap. The 8-pin octal socket is a standard industrial footprint.

Frequently asked questions

What is the closest pin-compatible alternative to the 61F-HSL AC110?

Within the 61F series, the 61F-GP-NH (110VAC) is a general-purpose level controller with the same 8-pin octal base and SPDT output but without the adjustable sensitivity feature. The 61F-HSL AC110's key differentiator is the 0 ~ 5MOhm sensitivity adjustment, which the GP-NH lacks.

What does the High/Low Level type mean on the 61F-HSL AC110?

The High/Low Level type means the controller provides two setpoints from a single unit: a high-level stop and a low-level start (or the reverse), enabling automatic fill-and-drain cycling without a separate low-level relay.

MPN
61F-HSL AC110