Omron 61F series, High/Low Level Controller, type 61F-I AC100/200, 100/200VAC supply, relay output SPDT 5A @ 220VAC, 0~4kOhm sensitivity, chassis mount, screw terminal.

$386.55 – $398.01Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

61F-I AC100/200 — Identification
ParameterValue
Series61F
61F-I AC100/200 — Contacts & Switching
ParameterValue
Contact formSPDT (2 Form C)
Contact rating at voltage5A @ 220VAC
61F-I AC100/200 — Coil & Supply
ParameterValue
Supply voltage range100/200VAC
61F-I AC100/200 — Function & Indication
ParameterValue
TypeHigh/Low Level
61F-I AC100/200 — Mechanical
ParameterValue
Mounting typeChassis Mount
Termination styleScrew Terminal
61F-I AC100/200 — Environmental
ParameterValue
Operating temperature range-10°C ~ 55°C
61F-I AC100/200 — Other specifications
ParameterValue
Weight1.7 lbs (771.1 g)
FeaturesLevel Indication
Output signalRelay
Sensitivity0 ~ 4kOhm
Distance - control to sensor1km

Product details

The Omron 61F-I AC100/200 is a High/Low Level controller from the 61F series, designed for conductive liquid level sensing in tanks, sumps, and process vessels. It operates on a 100/200VAC supply and provides relay output switching up to 5A at 220VAC, making it suitable for direct control of pumps, valves, or alarms. Sensitivity is adjustable from 0 to 4kOhm, which covers most conductive liquids including water, weak acids, and alkaline solutions. The 1km maximum distance between controller and sensor probe allows remote mounting away from the vessel.

Mounting and Termination

Chassis mount with screw terminals — no DIN-rail adapter, so plan panel space for a dedicated mounting footprint.

Key Ratings in Context

The SPDT (2 Form C) contact arrangement gives one normally-open and one normally-closed set, which can drive a pump fill/empty sequence or a high/low alarm independently. The 5A at 220VAC contact rating handles small motor starters or pilot relays directly; for larger loads, interpose a contactor.

Frequently asked questions

What is the 61F-I AC100/200 used for?

It is a conductive liquid level controller for high/low level detection in tanks, using probe electrodes and a relay output to control pumps or alarms.

What is the maximum distance between the controller and the sensor?

The rated maximum distance from control to sensor is 1 km, allowing the controller to be mounted remotely from the tank.

What sensitivity range does the 61F-I AC100/200 support?

Sensitivity is adjustable from 0 to 4 kOhm, covering most conductive liquids including water, weak acids, and alkaline solutions.