Skip to main content
Omron 61F-INH AC110/220 — General Purpose Relays

Omron 61F-INH AC110/220 Level Controller, High/Low, 110/220V

MPN61F-INH AC110/220
Active

Omron 61F series, High/Low Level Controller, 61F-INH AC110/220, 110/220VAC supply, SPDT (2 Form C) relay outputs, 10kOhm ~ 40kOhm sensitivity, DIN Rail mount, Screw Terminal.

$807.31 – $831.29Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

61F-INH AC110/220 — Identification
ParameterValue
Series61F
61F-INH AC110/220 — Contacts & Switching
ParameterValue
Contact formSPDT (2 Form C)
Contact rating at voltage3A @ 200VAC
61F-INH AC110/220 — Coil & Supply
ParameterValue
Supply voltage range110/220VAC
61F-INH AC110/220 — Function & Indication
ParameterValue
TypeHigh/Low Level
61F-INH AC110/220 — Mechanical
ParameterValue
Mounting typeDIN Rail
Termination styleScrew Terminal
61F-INH AC110/220 — Environmental
ParameterValue
Operating temperature range-10°C ~ 55°C
61F-INH AC110/220 — Other specifications
ParameterValue
Weight0.904 lb (410.05 g)
FeaturesAlarm High/Low - Contact, Level Indication
Output signalRelay (2)
Sensitivity10kOhm ~ 40kOhm
Distance - control to sensor50m

Product details

The Omron 61F-INH AC110/220 is a High/Low level controller from the 61F series, designed for conductive liquid level detection in tanks, sumps, and process vessels. It operates on a 110/220VAC supply and provides two SPDT (2 Form C) relay outputs rated at 3A @ 200VAC, giving you independent alarm and control contacts for fill or drain logic. Sensitivity is adjustable across 10kOhm to 40kOhm, which covers most conductive liquids — water, weak acids, coolants — without false triggering from foam or surface films. The control-to-sensor distance extends to 50m, so the controller can sit in a central panel while the probes are out at the vessel.

Mounts directly on a DIN rail in the enclosure. The dual SPDT relays share a common supply, so verify the load wiring doesn't exceed the 3A @ 200VAC rating per contact — derate if switching inductive loads like contactor coils. If the controller is near a steam valve or hot pipe, allow airflow or shift it to a cooler zone in the cabinet.

Frequently asked questions

What is the 61F-INH AC110/220 used for?

It is a High/Low level controller used to detect and control conductive liquid levels in tanks, sumps, or process vessels, providing relay outputs for alarms or pump control.

What are the key ratings for the 61F-INH AC110/220?

Key ratings include a 110/220VAC supply, two SPDT relay outputs rated at 3A @ 200VAC, adjustable sensitivity from 10kOhm to 40kOhm, and a maximum control-to-sensor distance of 50m.

Where can I buy the 61F-INH AC110/220?

The 61F-INH AC110/220 is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

MPN
61F-INH AC110/220