Skip to main content
Omron D4GS-N2T-5 — Limit Switches

Omron D4GS-N2T-5 Slim Safety Door Switch, 2NC, 5m Cable

MPND4GS-N2T-5

Omron D4GS-N2T-5 Slim Safety Door Switch, 2NC slow-action contacts, 5 m cable, vertical key insertion, 2.5 A Ith, 100 A conditional short-circuit current.

$130.81 – $189.00Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

D4GS-N2T-5 — Specifications
ParameterValue
Weight0.12 Kg
Cable length5 m
Product typeSlim Safety Door Switch
Built-in switch2 = 2NC (slow-action)
Operating speed0.1 to 0.5 m/s
Operating frequency30 operations/minute max
Conditional short-circuit current100 A (EN60947-5-1)
Direction of operation key insertionT = Vertical
Conventional free air thermal current2.5 A (EN60947-5-1)

Product details

The Omron D4GS-N2T-5 is a slim-profile safety door switch with two normally-closed (2NC) slow-action contacts, a 5 m cable, and vertical key insertion. It is designed for interlocking guard doors on industrial machinery where space is tight — the slim body fits where a standard safety switch would not. Rated conventional free-air thermal current (Ith) of 2.5 A per EN 60947-5-1, with a conditional short-circuit current of 100 A. Operating speed range of 0.1 to 0.5 m/s and a maximum operating frequency of 30 operations per minute define the mechanical limits for the door motion it can safely monitor.

The 2NC contact configuration is the safety-relevant pair — two normally-closed channels in series, which is the standard wiring for a dual-channel safety circuit feeding a safety relay or safety PLC. The slow-action contacts (not snap-action) mean the switch state changes at the speed the door moves, which is typical for guard interlocking where the actuator must be positively driven out of the switch body. Vertical key insertion (T suffix) means the actuator enters the switch from above. This determines the mounting orientation of the switch relative to the guard door hinge — critical to get right when replacing an existing switch in a panel or machine frame. The 5 m cable is factory-attached and permanently sealed into the switch body. No field-wiring or connector changes possible — the cable length is fixed, so plan the routing and junction box location accordingly.

Frequently asked questions

What is the key rating that determines fit for this switch?

The 2NC contact configuration and the 100 A conditional short-circuit current rating (EN 60947-5-1) are the primary fit criteria. The 2NC pair is required for dual-channel safety circuits, and the 100 A SCCR must be coordinated with the upstream fuse or breaker to ensure the switch clears a fault without welding its contacts.

What does the 'T' in D4GS-N2T-5 mean?

The 'T' indicates vertical key insertion direction — the actuator enters the switch from above. This determines the mounting orientation relative to the guard door hinge line.

MPN
D4GS-N2T-5