Omron D4SL-N4RDG-D4 Guard Locking Switch, 1300 N, 6 contacts

MPND4SL-N4RDG-D4

Omron D4SL-N series guard locking switch, D4SL-N4RDG-D4, solenoid lock/mechanical release, 1300 N holding force, 6 contacts (3 NC + 3 NC), 24 VDC solenoid, orange indicator, M20 conduit, metal head, terminal block connection.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

D4SL-N4RDG-D4 — Specifications
ParameterValue
IndicatorOrange, 24 VDC
Conduit sizeM20
Head materialMetal
Release key typeSpecial release key (resin)
Solenoid voltage24 VDC
Connection methodTerminal Block
Key holding force1300 N
Number of contacts6
Contact configuration3 NC + 3 NC
Door lock and releaseSolenoid lock/mechanical release

Product details

Guard locking switch with 1300 N holding force

The Omron D4SL-N4RDG-D4 is a guard locking switch from the D4SL-N series, designed for safety interlock applications where a monitored guard door must stay locked until safe conditions are confirmed. It delivers a holding force of 1300 N — enough to resist forced opening on heavy access doors or guards on automated cells, conveyors, and packaging machinery. The solenoid operates at 24 VDC, and the switch provides 6 contacts in a 3 NC + 3 NC configuration, giving redundant feedback to the safety controller. The metal head and M20 conduit entry suit industrial environments where mechanical impact and cable routing through standard metric fittings are expected. The orange indicator at 24 VDC gives a clear visual status of the solenoid state — energized or de-energized — for quick troubleshooting on the line. Connection is via terminal block, and the special release key (resin) allows manual override when power is removed, a requirement for maintenance access without defeating the safety circuit.

Integration notes

Mount the switch on the fixed frame of the guard door, aligning the actuator with the door-mounted cam. The M20 conduit entry accepts standard metric cable glands; route the 24 VDC solenoid supply and the six contact wires through the same entry. Terminal block wiring inside the switch body — strip length per the manufacturer's instruction, typically 7–8 mm. The orange indicator is visible from the side of the switch head, so orient the switch so the indicator faces the operator's line of sight.

Frequently asked questions

What is D4SL-N4RDG-D4's listed indicator?

The indicator is orange and operates at 24 VDC, providing a clear visual status of the solenoid state.

What is D4SL-N4RDG-D4's listed conduit size?

The conduit entry is M20, accepting standard metric cable glands.

What is the holding force of D4SL-N4RDG-D4?

The holding force is 1300 N, suitable for heavy guard doors where forced opening must be resisted.

What contact configuration does D4SL-N4RDG-D4 have?

It has 6 contacts in a 3 NC + 3 NC configuration, providing two independent safety channels for redundant monitoring.