The E2BM12LN08M1B1OMI: This E2B cylindrical inductive sensor is a non-flush M12 unit with an 8 mm sensing distance, rated for 10–30 VDC operation and a 200 mA load. The PNP normally-open output switches at up to 800 Hz, suitable for moderate-speed position sensing on ferrous targets. IP67 sealing handles washdown or wet area mounting. Current draw from the sensor itself is 10 mA.
Peer comparison
The closest functional sibling in the same family is the E2BS08KS02MCB120OMS, but it is a different sensor for a different job. That unit is a flush-mount M8 sensor with only 2 mm of sensing range, switching at 1.5 kHz in a smaller 13 × 13 × 44 mm stainless steel body with an M8 3-pin connector. This E2BM12LN08M1B1OMI cannot drop into a panel wired for the M8 peer without a connector change and will not sense the same targets due to the larger sensing distance and non-flush requirement. Choose this one where non-flush mounting and an 8 mm range are needed; the M8 peer is for flush mount and tight spaces.
Mounting & wiring
Non-flush mount; 8 mm sensing distance. Brass body 74×17 mm, M12 4-pin connector, IP67, –25 to 70 °C.