The E2BS08LS02MCB2OMI: M8 flush-mount inductive sensor with a 2 mm sensing distance and a 1.5 kHz switching frequency. Output is PNP break-contact (NC), drawing 10 mA quiescent and rated to switch 200 mA loads. The stainless steel housing carries IP67 protection, and the M8 3-pin connector mates with standard prewired cables or field-attachable plugs.
NC vs NO — same footprint, different output logic
The E2BS08LS02MCB2OMI is the NC variant. Its functional sibling, the E2BS08KS02MCB120OMS, shares the same 13 mm width, 13 mm height, 2 mm flush sensing distance, and 1.5 kHz switching frequency, but delivers a PNP make contact (NO) output. Both mount flush, both use the same M8 3-pin connector. If your panel was specified around the NO version, the NC part will bolt into the same hole pattern and pin out identically — but the PLC input logic must be inverted to accommodate the normally-closed switching. The physical swap is straightforward; the logic change is not.