Skip to main content
Omron E2E-X10MY2-US — Proximity Sensors

Omron E2E-X10MY2-US Proximity Sensor, SCR-NC, 10mm, M18, IP6

MPNE2E-X10MY2-US

Omron E2E series, Inductive Proximity Sensor, Cylinder Threaded - M18, Unshielded, 10mm Sensing Distance, SCR-NC 2-Wire, 20-264 VAC, Cable Leads, IP67.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

E2E-X10MY2-US — Identification
ParameterValue
SeriesE2E
E2E-X10MY2-US — Sensing
ParameterValue
Sensing distance0.394" (10mm)
ShieldingUnshielded
E2E-X10MY2-US — Environmental
ParameterValue
Operating temperature range-40°C ~ 85°C
E2E-X10MY2-US — Other specifications
ParameterValue
CaseCylinder, Threaded - M18
IndicatorLED
Output signalSCR-NC, 2-Wire
Sensor typeInductive
Material - bodyNickel-Plated Brass
Supply voltage20 VAC ~ 264 VAC
Termination styleCable Leads
IP ratingIP67
Response frequency25Hz

Product details

The Omron E2E-X10MY2-US is a current-production inductive proximity sensor in the E2E series, designed for AC circuits with a two-wire SCR output that is normally closed (NC). Its 10mm sensing distance, M18 threaded cylindrical body, and IP67 sealing make it a standard drop-in for general industrial presence detection in wet or dusty environments.

Output type and voltage — what this means for fit

This sensor has an SCR (thyristor) output that switches AC loads from 20 VAC to 264 VAC. The NC output is ON when no target is present. Note that because this is a 2-wire SCR output, it is not compatible with DC supplies or transistor-based PLC inputs without an interface relay. Verify your control voltage type before specifying.

The M18 threaded body (nickel-plated brass) mounts with two jam nuts or a bracket. Unshielded construction gives the full 10mm sensing range but requires non-ferrous material-free zone around the face — standard practice for flush mounting in steel demands a shielded variant. Cable leads (2 meters, typically) terminate in a junction box or directly to a terminal; no quick-disconnect option on this version.

Frequently asked questions

What is the output type of this sensor?

The E2E-X10MY2-US has an SCR (thyristor) output that is normally closed (NC) and two-wire, designed for AC circuits from 20 VAC to 264 VAC.

What mounting form factor does this sensor use?

It has an M18 threaded cylindrical body, unshielded, with a 10mm sensing distance and cable leads. The case rating is IP67 for dust and water ingress.

MPN
E2E-X10MY2-US