E2EX16MB1T185MOMS — Identification
ParameterValue
SeriesE2E-Next
E2EX16MB1T185MOMS — Sensing
ParameterValue
Sensing distance, max.16 mm
E2EX16MB1T185MOMS — Electrical
ParameterValue
Operating voltage, max.30 V
Operating voltage, min.10 V
Termination typeCable, 5 m
E2EX16MB1T185MOMS — Output
ParameterValue
Switching frequency400 Hz
Load current200 mA
E2EX16MB1T185MOMS — Mechanical
ParameterValue
Mounting typeNon Flush Mount
Length55.3 mm
Housing materialBrass Nickel Plated
E2EX16MB1T185MOMS — Environmental
ParameterValue
Operating temperature, max.85 °C
Operating temperature, min.-40 °C
IP protection ratingIP67;IP67G;IP69K
E2EX16MB1T185MOMS — Other specifications
ParameterValue
Construction formM18
Current consumption16 mA
Inductive sensor output typePNP, NO

Product details

M18 non-flush inductive sensor – IP69K, 400 Hz

The Omron E2EX16MB1T185MOMS is an M18 non-flush inductive sensor from the E2E-Next series. It delivers 16 mm sensing distance at 400 Hz switching frequency – fast enough to see clear PET bottles flying past on a filler line. The brass nickel-plated housing and IP67/IP67G/IP69K rating mean it shrugs off washdown spray and high-pressure cleaning routines common in food and beverage plants. Rated for 10–30 VDC supply with 16 mA consumption, it sinks up to 200 mA load current on the PNP NO output. The 5 m cable is pre-attached – no connector to miswire or lose, but plan your cable run: if the sensor sits more than 5 m from the PLC input module, you’ll need a junction box or a field-wireable extension (the M12 connector sibling is one option for shorter runs).

Cable or connector – pick the termination that fits your panel

This 5 m cable version (E2EX16MB1T185MOMS) is mechanically identical to the 2 m cable variant (E2EX16MB1T182MOMS) – same 55.3 mm body, same sensing head, same IP rating. The only difference is the cable length; use the longer cable when the sensor is far from the control cabinet, the shorter one when a local junction box is planned. This 5 m cable version is 55.3 mm long. The M12 connector siblings are 53 mm and 75 mm long; choose one for tool-free swaps.

Frequently asked questions

What are the key ratings of this sensor?

M18 non-flush inductive sensor, 16 mm sensing distance, 400 Hz switching frequency, PNP NO output, 10–30 VDC supply, 16 mA consumption, 200 mA load rating, IP67/IP67G/IP69K protection, 5 m cable termination.

MPN
E2EX16MB1T185MOMS