Skip to main content
Omron E2EX16MB2L18M1OMS — Proximity Sensors

Omron E2EX16MB2L18M1OMS M18 Non-Flush Sensor, 16mm PNP NC

MPNE2EX16MB2L18M1OMS

Omron E2E-Next inductive sensor, M18 non-flush, PNP NC, 16 mm sensing distance, M12 4-pin connector, IP67/IP69K, 400 Hz switching.

$60.97Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

E2EX16MB2L18M1OMS — Identification
ParameterValue
SeriesE2E-Next
E2EX16MB2L18M1OMS — Sensing
ParameterValue
Sensing distance, max.16 mm
E2EX16MB2L18M1OMS — Electrical
ParameterValue
Operating voltage, max.30 V
Operating voltage, min.10 V
Termination typeConnector, M12, 4-Pin
E2EX16MB2L18M1OMS — Output
ParameterValue
Switching frequency400 Hz
Load current200 mA
E2EX16MB2L18M1OMS — Mechanical
ParameterValue
Mounting typeNon Flush Mount
Length75 mm
Housing materialBrass Nickel Plated
E2EX16MB2L18M1OMS — Environmental
ParameterValue
Operating temperature, max.85 °C
Operating temperature, min.-40 °C
IP protection ratingIP67;IP69K
E2EX16MB2L18M1OMS — Other specifications
ParameterValue
Construction formM18
Current consumption16 mA
Inductive sensor output typePNP, NC

Product details

The E2EX16MB2L18M1OMS: Compared to the flush-mount M12 E2AM12KS04M1B14OMS, this M18 non-flush sensor has a much larger detection zone (16 mm vs 4 mm) and a different output logic (NC vs NO) — not a panel swap without rewiring and re-machining the mounting hole.

With set to 'current', Omron continues to manufacture this part, so no LTB rush needed today.

Rated IP67/IP69K and brass nickel-plated body. The 400 Hz switching frequency handles fast part detection on a pick-and-place cycle. Supply at 10–30 VDC, 16 mA quiescent. Length is 75 mm — fits standard M18 shielded mounting arrangements for non-flush installations. M12 connector saves panel wiring time versus pigtail.

Frequently asked questions

What is the sensing distance and output type?

The sensing distance is 16 mm, and the output is PNP normally closed (NC) with a 200 mA load capacity.

Will this sensor drop into a panel designed for E2AM12KS04M1B14OMS?

No — that peer is a flush-mount M12 with 4 mm sensing and NO output, while this is non-flush M18 with 16 mm and NC. Requires different mounting hole and rewiring.

What are the key environmental ratings?

IP67 and IP69K, operating temperature -40 to 85 °C, and housing is brass nickel-plated for washdown resistance.

MPN
E2EX16MB2L18M1OMS