Skip to main content
Omron E2EX2Y12MOMS — Proximity Sensors

Omron E2EX2Y12MOMS M12 Inductive Sensor, NO, 2mm, IP67

MPNE2EX2Y12MOMS

Omron E2E-X series, M12 flush inductive proximity sensor, Make Contact (NO), 2 mm sensing distance, 200 mA, 20–264 VAC/DC, IP67, 2 m cable.

$158.40 – $185.04Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

E2EX2Y12MOMS — Identification
ParameterValue
SeriesE2E-X
E2EX2Y12MOMS — Sensing
ParameterValue
Sensing distance, max.2 mm
E2EX2Y12MOMS — Electrical
ParameterValue
Operating voltage, max.264 V
Operating voltage, min.20 V
Termination typeCable, 2 m
E2EX2Y12MOMS — Output
ParameterValue
Switching frequency25 Hz
Load current200 mA
E2EX2Y12MOMS — Mechanical
ParameterValue
Mounting typeFlush Mount
Length43 mm
Housing materialBrass
E2EX2Y12MOMS — Environmental
ParameterValue
Operating temperature, max.85 °C
Operating temperature, min.-40 °C
IP protection ratingIP67

Product details

The Omron E2EX2Y12MOMS is a flush-mount M12 inductive proximity sensor that makes contact when it sees ferrous metal within 2 mm. Rated across 20–264 VAC/DC, it handles a 200 mA load and switches at 25 Hz—fast enough for pitch-position feedback or blade-pitch limit stops up-tower. Operating temperature range -40 to 85°C. Repeat accuracy 10% holds across the full range.

Same housing: 21 mm square, 43 mm deep, M12 brass barrel, same flush mount, same 2 m cable, same 2 mm sensing distance. The critical difference is output logic: this one goes to NO (make on target), the E2EX2Y22MOMS is NC (break on target). If your panel was wired for an NC prox (e.g., safety-circuit series chain), dropping in this NO sensor means rewiring the load or inverting the PLC input logic. Also note the temperature range: this one handles -40 to 85°C while the NC peer only covers -25 to 70°C—a real difference if you're mounting on a nacelle roof exposed to low extremes.

Frequently asked questions

Can I substitute the E2EX2Y22MOMS (NC output) with this NO version without rewiring?

Physically it fits—same dimensions, mount, cable, and sensing distance. But the output type is opposite (NO vs NC), so you must either rewire the load to switch on the opposite state or invert the logic in your controller. The NO sensor also has a wider temperature range (-40 to 85°C) than the NC peer (-25 to 70°C).

What are the key ratings of this sensor?

It is a flush-mount M12 inductive sensor, NO output, 2 mm sensing distance, 200 mA load current, operating voltage 20–264 VAC/DC, switching frequency 25 Hz, IP67, brass housing, 2 m cable, repeat accuracy 10%, and operating temperature -40 to 85°C.

MPN