E2EX2Y22MOMS — Identification
ParameterValue
SeriesE2E-X
E2EX2Y22MOMS — Sensing
ParameterValue
Sensing distance, max.2 mm
E2EX2Y22MOMS — Electrical
ParameterValue
Operating voltage, max.264 V
Operating voltage, min.20 V
Termination typeCable, 2 m
E2EX2Y22MOMS — Output
ParameterValue
Switching frequency25 Hz
Load current200 mA
E2EX2Y22MOMS — Mechanical
ParameterValue
Mounting typeFlush Mount
Length43 mm
Housing materialBrass
E2EX2Y22MOMS — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
IP protection ratingIP67

Product details

Omron E2EX2Y22MOMS is a M12 flush-mount inductive proximity sensor from the E2E-X series. It detects ferrous targets at 2 mm, switches 200 mA loads at up to 264 VAC/VDC, and outputs a normally-closed (NC) signal. Rated IP67 with a 2 m PVC cable, it suits machine-tool feedback, conveyor presence, and hydraulic valve position in tight metal surroundings.

NC vs NO: choosing the right output logic

Compared to the near-identical sibling E2EX2Y12MOMS (NO output), this NC variant offers fail-safe under cable break: the output goes open when the sensor loses power or the cable is severed. The trade-off is a tighter temperature range (-25 to 70 °C versus -40 to 85 °C on the NO sibling). For panel layouts already wired for NC, this part drops in without rewiring the PLC input card; the terminal assignment is identical.

Panel fit and installation

Mounts in a 12 mm bored hole with the brass barrel; the 21 mm hex body takes a standard 21 mm wrench. The 2 m cable exits axially, so gland or connector planning needs clearance behind the sensor. Flush-mount permits embedment in steel without derating the 2 mm sensing distance — no extra standoff required.

Frequently asked questions

Will E2EX2Y22MOMS drop into a panel wired for E2EX2Y12MOMS without rewiring?

No — the NC output on this part reverses the signal logic. The terminal connections are the same but the PLC input configuration must match the fail-safe state. A sensor-to-PLC cable swap alone will not work.

What is the physical size of this sensor?

Body diameter M12, total length 43 mm, hex width 21 mm. The cable adds 2 m of flexible PVC.