Skip to main content
Omron E2EX30MB1TL305MOMS — Proximity Sensors

Omron E2EX30MB1TL305MOMS E2E-Next Inductive Sensor, PNP NO 3

MPNE2EX30MB1TL305MOMS

Omron E2E-Next inductive proximity sensor, M30 non-flush, PNP NO output, 30 mm sensing distance, 100 Hz switching frequency, 5 m cable, IP67 / IP67G / IP69K.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

E2EX30MB1TL305MOMS — Identification
ParameterValue
SeriesE2E-Next
E2EX30MB1TL305MOMS — Sensing
ParameterValue
Sensing distance, max.30 mm
E2EX30MB1TL305MOMS — Electrical
ParameterValue
Operating voltage, max.30 V
Operating voltage, min.10 V
Termination typeCable, 5 m
E2EX30MB1TL305MOMS — Output
ParameterValue
Switching frequency100 Hz
Load current200 mA
E2EX30MB1TL305MOMS — Mechanical
ParameterValue
Mounting typeNon Flush Mount
Length82.3 mm
Housing materialBrass Nickel Plated
E2EX30MB1TL305MOMS — Environmental
ParameterValue
Operating temperature, max.85 °C
Operating temperature, min.-40 °C
IP protection ratingIP67;IP67G;IP69K
E2EX30MB1TL305MOMS — Other specifications
ParameterValue
Construction formM30
Current consumption16 mA
Inductive sensor output typePNP, NO

Product details

Tight integrator note

The E2EX30MB1TL305MOMS: This E2E-Next M30 non-flush inductive sensor detects ferrous metals up to 30 mm with a PNP normally-open output. Switching frequency at 100 Hz keeps up with moderate-speed part detection on packaging lines and conveyor transfer stations. Powered from a 10–30 VDC supply, it draws 16 mA; the 200 mA load current handles direct PLC inputs or small relays. The 5 m cable saves an additional junction box in many installations — run it straight back to the control cabinet if the run allows. Rated IP67, IP67G (gas-tight), and IP69K for high-pressure washdown environments — common in food and beverage packaging lines.

Cable-length and output comparisons

Compared to the 2 m cable version (E2EX30MB1TL302MOMS), this 5 m variant adds three meters of cable. No other electrical or mechanical difference — same M30 non-flush body, same 30 mm sensing distance, same switching frequency and output. The connector version (E2EX30MB1TL30M1OMS) is 2 mm shorter at 80 mm and uses an M12 connector rather than fixed cable. If your panel layout requires a connector for quick-change or the cable would be too long, that's the candidate. But the 5 m cable version is the simpler, one-piece solution for a fixed installation. For a normally-closed output, the E2EX30MB2L302MOMS (2 m cable, PNP NC) swaps the contact logic; the rest is identical.

Frequently asked questions

What is the sensing distance and output type?

Sensing distance is 30 mm, output is PNP normally open.

How does it compare to E2EX30MB1TL302MOMS?

The only difference is cable length: 5 m versus 2 m. Same sensing distance, output, switching frequency, and housing dimensions.

What is the protection rating?

Rated IP67, IP67G, and IP69K for high-pressure washdown environments.

MPN
E2EX30MB1TL305MOMS