Skip to main content
Omron E2EX8B1T185MOMS — Proximity Sensors

Omron E2EX8B1T185MOMS E2E-Next Inductive Sensor, PNP NO 8mm

MPNE2EX8B1T185MOMS

Omron E2E-Next series, M18 flush-mount inductive sensor, PNP normally open, 8 mm sensing distance, 5 m cable, 10–30 VDC, 500 Hz switching frequency, IP67/IP67G/IP69K, brass nickel-plated housing.

$87.80 – $99.50Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

E2EX8B1T185MOMS — Identification
ParameterValue
SeriesE2E-Next
E2EX8B1T185MOMS — Sensing
ParameterValue
Sensing distance, max.8 mm
E2EX8B1T185MOMS — Electrical
ParameterValue
Operating voltage, max.30 V
Operating voltage, min.10 V
Termination typeCable, 5 m
E2EX8B1T185MOMS — Output
ParameterValue
Switching frequency500 Hz
Load current200 mA
E2EX8B1T185MOMS — Mechanical
ParameterValue
Mounting typeFlush Mount
Length55.3 mm
Housing materialBrass Nickel Plated
E2EX8B1T185MOMS — Environmental
ParameterValue
Operating temperature, max.85 °C
Operating temperature, min.-40 °C
IP protection ratingIP67;IP67G;IP69K
E2EX8B1T185MOMS — Other specifications
ParameterValue
Construction formM18
Current consumption16 mA
Inductive sensor output typePNP, NO

Product details

This is the E2E-Next series flush-mount M18 inductive proximity sensor, order code E2EX8B1T185MOMS. It switches a PNP normally-open output at 500 Hz when it detects a metal target within 8 mm. The 5 m PVC cable suits longer wiring runs in wet environments; the housing is brass nickel-plated to stand up to corrosion, and the triple ingress rating (IP67/IP67G/IP69K) means it can be hose-down cleaned and survive gases – important for wastewater lift stations and food-processing washdown zones.

Cable length vs alternatives

The only parametric difference between the 5 m cable variant and the 2 m sibling (E2EX8B1T182MOMS) is cable length; both are 55.3 mm long. The M12 connector variant (E2EX8B1T18M1OMS) is 53 mm long and rated IP67/IP69K but not IP67G; if the application requires gas ingress protection (sewage gas, chemical atmospheres), the cable version is the one to specify.

Flush mounting: the sensor can be embedded in a metal panel without the typical sensing distance reduction that non-flush sensors need. Works on 10–30 VDC, draws 16 mA plus the 200 mA load. The 500 Hz switching frequency handles fast-moving parts on conveyor lines.

Frequently asked questions

What is the length of this sensor?

55.3 mm.

What series is this sensor from?

The E2E-Next series.

MPN
E2EX8B1T185MOMS