Skip to main content
Omron E2EX8MB1TL12M1OMS — Proximity Sensors

Omron E2EX8MB1TL12M1OMS, M12 Non-Flush, 8mm, PNP NO, IP69K

MPNE2EX8MB1TL12M1OMS

Omron E2E-Next series, E2EX8MB1TL12M1OMS, M12 non-flush inductive sensor, 8 mm sensing distance, PNP normally open, 10-30 VDC, IP67/IP69K.

$60.97Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

E2EX8MB1TL12M1OMS — Identification
ParameterValue
SeriesE2E-Next
E2EX8MB1TL12M1OMS — Sensing
ParameterValue
Sensing distance, max.8 mm
E2EX8MB1TL12M1OMS — Electrical
ParameterValue
Operating voltage, max.30 V
Operating voltage, min.10 V
Termination typeConnector, M12, 4-Pin
E2EX8MB1TL12M1OMS — Output
ParameterValue
Switching frequency800 Hz
Load current200 mA
E2EX8MB1TL12M1OMS — Mechanical
ParameterValue
Mounting typeNon Flush Mount
Length70 mm
Housing materialBrass Nickel Plated
E2EX8MB1TL12M1OMS — Environmental
ParameterValue
Operating temperature, max.85 °C
Operating temperature, min.-40 °C
IP protection ratingIP67;IP69K
E2EX8MB1TL12M1OMS — Other specifications
ParameterValue
Construction formM12
Current consumption16 mA
Inductive sensor output typePNP, NO

Product details

What this sensor is and what it handles

The Omron E2EX8MB1TL12M1OMS is an M12 non-flush inductive sensor from the E2E-Next series, rated IP69K for high-pressure washdown — a sensor that takes the caustic CIP without complaint. Switching at 800 Hz, it detects ferrous targets at 8 mm with a PNP normally open output, on a 10-30 VDC supply drawing 16 mA. The brass nickel-plated housing withstands the thermal and chemical stress of a brewery washdown cycle.

Non-flush mount means the sensing face must project beyond any surrounding metal — no recessing into a metal block without losing distance. Plan a hold-down bracket or standoff to maintain the air gap. The M12 4-pin connector mates with standard prewired cordsets. Rated from -40 to 85 °C, with IP67 and IP69K protection for washdown environments.

If you're evaluating against the E2AM12KS04M1B14OMS, the main difference is mounting: this non-flush sensor requires a non-flush environment, while that one is designed for flush mounting. The sensing distance also differs — 8 mm here vs 4 mm on the flush sibling — so a straight swap isn't a given. Match the mounting type and distance your application calls for.

Frequently asked questions

What is the closest functional second-source?

The E2AM12KS04M1B14OMS is a flush-mount M12 sensor with a 4 mm sensing distance, PNP NO output, and the same IP rating. However, the mounting requirement (flush vs non-flush) and sensing distance differ, so a drop-in swap requires verifying the application's mounting conditions.

What is the sensor's length?

The length is 70 mm.

MPN
E2EX8MB1TL12M1OMS