Skip to main content
Omron E2SQ261MOMS — Proximity Sensors

Omron E2SQ261MOMS Inductive Sensor, NC, 2.5mm, 9mm, IP67

MPNE2SQ261MOMS

Omron E2SQ261MOMS, E2S series, inductive proximity sensor, break contact (NC), 2.5 mm sensing, 9 mm × 9 mm × 23 mm, 1 m cable, IP67.

$93.80Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

E2SQ261MOMS — Identification
ParameterValue
SeriesE2S
E2SQ261MOMS — Sensing
ParameterValue
Sensing distance, max.2.5 mm
E2SQ261MOMS — Electrical
ParameterValue
Operating voltage, max.30 V
Operating voltage, min.10 V
Termination typeCable, 1 m
E2SQ261MOMS — Output
ParameterValue
Switching frequency1 kHz
Load current50 mA
E2SQ261MOMS — Mechanical
ParameterValue
Mounting typeNon Flush Mount
Length23 mm
Housing materialPlastic
E2SQ261MOMS — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
IP protection ratingIP67

Product details

Omron E2SQ261MOMS is an E2S series inductive proximity sensor with a normally closed (NC) output. It detects ferrous targets at 2.5 mm non-flush and switches at up to 1 kHz, carrying a 50 mA load over 10–30 VDC. The 9 mm cube housing is rated IP67, suitable for washdown areas or dusty environments. Current consumption is 13 mA; the 1 m cable terminates the connection.

NC vs. NO – how the output type affects your choice

The exact same form factor, sensing distance, and electrical ratings appear on the NO sibling E2SQ211MOMS. The only difference is the output state: this part opens its load circuit when a target is present (break contact), while the NO version closes the circuit on target. Physical fit in a 9 mm panel cutout, cable length, and mounting are identical, so a board swap is possible – but the logic inversion means you must verify whether the downstream input expects a normally open or normally closed signal. For a safety or fault-annunciation circuit where a loss of sensor signal (wire break) must be detected, the NC configuration is the standard fail-safe choice.

Frequently asked questions

What are the key dimensions?

The housing is a 9 mm × 9 mm square with a depth of 23 mm. The cable is 1 m long.

Will the NC version drop into a panel designed for the NO version E2SQ211MOMS?

Physically yes – identical footprint, mounting, and electrical ratings. However, the output logic is inverted. If the controller expects a normally open signal (closes on target), this NC sensor will open on target, which may trigger an alarm or stop the process unless the input logic is reprogrammed or rewired. Verify the input type before substituting.

What is the sensing distance and switching frequency?

Rated sensing distance is 2.5 mm (non-flush mount). Maximum switching frequency is 1 kHz.

MPN
E2SQ261MOMS