Specifications

E3NXFA11AN2MOMS — Identification
ParameterValue
SeriesE3NX-FA
Sensor typeFibre Amplifier Unit
E3NXFA11AN2MOMS — Sensing
ParameterValue
Response time30 us
Light typeLED, Red
E3NXFA11AN2MOMS — Electrical
ParameterValue
Operating voltage, min.10 V
Operating voltage, max.30 V
E3NXFA11AN2MOMS — Output
ParameterValue
Output typeNPN
Load current100 mA
Switching typeLight-ON / Dark-ON
E3NXFA11AN2MOMS — Connection
ParameterValue
Termination typeCable, 2 m
E3NXFA11AN2MOMS — Environmental
ParameterValue
Operating temperature, min.-25 °C
Operating temperature, max.55 °C
E3NXFA11AN2MOMS — Mechanical
ParameterValue
Length71.8 mm
Width10 mm
Height33.5 mm

Product details

The E3NXFA11AN2MOMS: NPN fibre amplifier, 30 µs response, 100 mA load current. Takes 10–30 V supply, red LED for glass or plastic fibres. Light-ON / Dark-ON selectable. The 10 mm wide housing fits the E3NX-FA base; cable exits at 2 m. Ambient range -25 to 55 °C. Response time is 30 µs — fast enough for small-part detection at moderate line speeds. The NPN output sinks up to 100 mA, enough to drive a compact PLC input or small relay directly.

NPN vs PNP — the decision difference

Step to this NPN version if your PLC sinks current. For sourcing inputs, use the PNP variant with identical dimensions, cable, and response. The earlier E3NX-MA series brother (E3NXMA412MOMS) runs 100 µs response and adds an IP50 rating but shares the same mounting footprint. For speed-critical lines, stick with the 30 µs E3NX-FA.

Frequently asked questions

What is the width of this fibre amplifier?

10 mm. It mounts on the standard E3NX-FA DIN-rail base.

What is the height of this fibre amplifier?

33.5 mm.

Will E3NXFA11AN2MOMS drop into a panel that was specified around E3NXFA512MOMS without rewiring?

No. The mechanical footprint and cable are identical, but the output type differs — NPN vs PNP. The load wiring to the PLC input must be changed to suit sinking vs sourcing logic.