What the output mix means on the panel
The E5CC-QQ3D5M-006 carries three relay outputs and two voltage outputs for driving external SSRs. That split lets it switch contactors or solenoid valves through the relays while the voltage outputs fire solid-state relays for heater or cooler loads — no need to add interposing relays for the SSR drive. The 24 VAC/DC supply means it can share a control transformer with PLCs and sensors, or run off a 24 VDC power supply in a cabinet where line voltage isn't routed to the door.
Sensor input flexibility and panel fit
It accepts RTD plus 14 thermocouple types (B, E, J, K, L, N, PLII, R, S, T, U, W) and 0–20 mA or 0–10 VDC analog signals — so one part number covers thermocouple, RTD, and process transmitter inputs without a separate input module. The 45 mm square panel cutout is the standard 1/16 DIN size — it drops into existing holes without adapter plates. IP66 front rating means it handles washdown in food or chemical environments without a protective cover.
Sourced to order against the BOM quantity; current pricing and availability confirmed at RFQ through independent distribution.