Skip to main content
Omron E5CC-RW2AUM-000 — Process / Temperature Controllers

Omron E5CC-RW2AUM-000 Temperature Controller, Octal Plug-In

MPNE5CC-RW2AUM-000
Active

Omron E5CC Series, Process/Temperature Controller, E5CC-RW2AUM-000, 1/16 DIN, 100~240 VAC, Relay (3) Output, Plug In Octal Termination.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

E5CC-RW2AUM-000 — Identification
ParameterValue
SeriesE5CC
TypeProcess, Temperature Controller (RTD, Type B, E, J, K, L, N, PLII, R, S, T, U, W)
E5CC-RW2AUM-000 — Electrical
ParameterValue
Supply voltage100 ~ 240VAC
E5CC-RW2AUM-000 — Performance
ParameterValue
Control methodOn/Off, Proportional (PID)
E5CC-RW2AUM-000 — I/O
ParameterValue
Input range-200°C ~ 2300°C, 0 ~ 20mA, 0 ~ 10VDC
Output typeRelay (3)
E5CC-RW2AUM-000 — Display
ParameterValue
Display typeLCD - Dual Color Characters, Backlight
Characters per row4, 4
Character height0.600" (15.20mm), 0.280" (7.10mm)
E5CC-RW2AUM-000 — Environmental
ParameterValue
Operating temperature-10°C~55°C
Ingress protection (IP rating)IP66 - Dust Tight, Water Resistant
E5CC-RW2AUM-000 — Mechanical
ParameterValue
Mounting typePanel Mount
Panel cutout dimensionsSquare - 45.00mm x 45.00mm
Termination stylePlug In, 11 Pin (Octal)
E5CC-RW2AUM-000 — Other specifications
ParameterValue
Weight0.265 lb (120.2 g)

Product details

Field-replaceable controller with octal base

The Omron E5CC-RW2AUM-000 is a 1/16 DIN temperature controller that accepts RTD, thermocouple (B, E, J, K, L, N, PLII, R, S, T, U, W), 0–20 mA, or 0–10 VDC inputs. Three relay outputs handle on/off or PID control. The plug-in octal base (11-pin) means you can swap the controller in seconds without pulling wires — just unplug the old one, plug in the new. If you're servicing a panel in the field, that's the difference between a 10-minute swap and a retermination job.

Why this one vs the screw-terminal peers

Compared to the E5CC-CX3A5M-006 (screw terminal, analog + relay output), the RW2AUM-000 gives up the analog output channel but keeps three relays. The real difference is the termination: octal plug-in vs screw clamp. If the existing panel has a socket base, this drops right in. If it's wired to screw terminals, you're swapping the base too — or stick with the screw-terminal version. No difference in input range, cutout, or supply voltage.

Panel prep — standard 1/16 DIN cutout

Square cutout 45.00 x 45.00 mm. IP66 front rating, operates from -10°C to 55°C.

Frequently asked questions

What's the closest functional second-source if I can't get this exact MPN?

The E5CC-CX3A5M-006 is a close sibling but uses screw terminals instead of octal plug-in — so the base socket differs. It also swaps one relay output for an analog output.

What types of sensors does this controller accept?

It accepts RTD, thermocouple types B, E, J, K, L, N, PLII, R, S, T, U, W, as well as 0–20 mA and 0–10 VDC analog inputs.

Will the E5CC-RW2AUM-000 drop into a panel wired for an E5CC-CX3A5M-006?

No — the RW2AUM-000 uses an octal plug-in base, while the CX3A5M-006 uses screw terminals. The panel would need a socket base for the RW2AUM-000 to plug in, or you would need to re-terminate.

MPN
E5CC-RW2AUM-000