Skip to main content
Omron E5DC-RX0DBM-015 — Process / Temperature Controllers

Omron E5DC-RX0DBM-015 Temperature Controller, Relay Out

MPNE5DC-RX0DBM-015
Active

Omron E5DC Series, Process / Temperature Controller, DIN Rail, Relay Output, LCD Dual-Color Display, 24VAC/DC Supply, RS-485 CompoWay/F & Modbus.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

E5DC-RX0DBM-015 — Identification
ParameterValue
SeriesE5DC
TypeProcess, Temperature Controller (RTD, Type B, E, J, K, L, N, PLII, R, S, T, U, W)
E5DC-RX0DBM-015 — Electrical
ParameterValue
Supply voltage24VAC/DC
E5DC-RX0DBM-015 — Performance
ParameterValue
Control methodOn/Off, Proportional (PID)
E5DC-RX0DBM-015 — I/O
ParameterValue
Input range-200°C ~ 2300°C, 0 ~ 20mA, 0 ~ 10VDC
Output typeRelay
E5DC-RX0DBM-015 — Communication
ParameterValue
Communication interfacesRS-485 (CompoWay/F, Modbus)
E5DC-RX0DBM-015 — Display
ParameterValue
Display typeLCD - Dual Color Characters, Backlight
Characters per row4, 4
Character height0.334" (8.50mm), 0.314" (8.00mm)
E5DC-RX0DBM-015 — Environmental
ParameterValue
Operating temperature-10°C ~ 55°C
Ingress protection (IP rating)IP20
E5DC-RX0DBM-015 — Mechanical
ParameterValue
Mounting typeDIN Rail
Termination styleSpring Terminal

Product details

DIN-Rail PID with Universal Input

The Omron E5DC-RX0DBM-015 is a DIN-rail-mount temperature controller that accepts RTD and 11 thermocouple types (B, E, J, K, L, N, PLII, R, S, T, U, W) plus 0–20 mA and 0–10 VDC analog signals — so one part number covers most process sensors on a panel without swapping modules.

Relay Output and Modbus on 24 V

The single relay output drives contactors or alarms directly; for a second control loop or heater-break alarm, step up to the E5DC-QX2DSM-017 which adds a second relay plus voltage output for an external SSR. Built-in RS-485 with both CompoWay/F and Modbus protocols lets this controller talk to a PLC or SCADA without a separate gateway — useful for retrofitting older lines where the fieldbus is already Modbus RTU. Powered by 24 VAC or DC, so it fits control panels that already run 24 VDC sensors and relays without a separate transformer tap.

Frequently asked questions

Where can I buy E5DC-RX0DBM-015 available via RFQ confirmation?

This part is sourced to order against an RFQ through independent distribution.

Does E5DC-RX0DBM-015 support RS-485 Modbus communication?

Yes, it supports RS-485 with both CompoWay/F and Modbus protocols built in.

What sensors can the E5DC-RX0DBM-015 work with?

It accepts RTD, thermocouple types B, E, J, K, L, N, PLII, R, S, T, U, W, plus 0–20 mA and 0–10 VDC analog inputs.

What are alternatives or cross references to E5DC-RX0DBM-015?

The closest functional sibling is the E5DC-QX2DSM-017, which adds a second relay output and a voltage output for an external SSR, plus heater fault detection and an event input. Both share the same DIN-rail form factor and 24 VAC/DC supply.

MPN
E5DC-RX0DBM-015