Omron E5EC-CC4A5M-014 — Process / Temperature Controllers

Omron E5EC-CC4A5M-014 Process/Temp Controller, 100-240VAC

MPNE5EC-CC4A5M-014
Active

Omron E5EC series process/temperature controller, universal input, 2 analog + 4 relay outputs, RS-485 communications, 100-240 VAC supply, IP66-rated face, panel mount.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

E5EC-CC4A5M-014 — Identification
ParameterValue
SeriesE5EC
TypeProcess, Temperature Controller (RTD, Type B, E, J, K, L, N, PLII, R, S, T, U, W)
E5EC-CC4A5M-014 — Electrical
ParameterValue
Supply voltage100 ~ 240VAC
E5EC-CC4A5M-014 — Performance
ParameterValue
Control methodOn/Off, Proportional (PID)
FeaturesEvent Input
E5EC-CC4A5M-014 — I/O
ParameterValue
Input range-200°C ~ 2300°C, 0 ~ 20mA, 0 ~ 10VDC
Output typeAnalog (2), Relay (4)
E5EC-CC4A5M-014 — Communication
ParameterValue
Communication interfacesRS-485 (CompoWay/F, Modbus)
E5EC-CC4A5M-014 — Display
ParameterValue
Display typeLCD - Tri Color Characters, Backlight
Characters per row4, 4, 4
Character height0.710" (18.00mm), 0.433" (11.00mm), 0.307" (7.80mm)
E5EC-CC4A5M-014 — Environmental
ParameterValue
Operating temperature-10°C~55°C
Ingress protection (IP rating)IP66 - Dust Tight, Water Resistant
E5EC-CC4A5M-014 — Mechanical
ParameterValue
Mounting typePanel Mount
Panel cutout dimensionsRectangular - 92.00mm x 45.00mm
Termination styleScrew Terminal
E5EC-CC4A5M-014 — Other specifications
ParameterValue
Weight0.463 lb (210.01 g)

Product details

Universal input, multi-output architecture for process loops

The Omron E5EC-CC4A5M-014 accepts RTD, thermocouple types B/E/J/K/L/N/PLII/R/S/T/U/W, plus 0-20 mA and 0-10 VDC process signals — one SKU covers temperature and linear process loops without a signal conditioner card. Two analog outputs and four relay outputs let it drive a valve positioner or SCR power controller while simultaneously alarming on high/low process deviation — that's another SKU I don't need for a separate alarm unit. The RS-485 port speaks Modbus and CompoWay/F, so it drops into a PLC-based line control scheme or a standalone HMI network without a protocol gateway.

Panel fit and environmental sealing

Panel cutout is 92.00 mm x 45.00 mm — the standard 1/4 DIN footprint. Screw terminals on the back; no special crimp tool needed for field wiring. IP66 rating on the face means it withstands washdown spray in food or chemical plants — the gasket seals against the panel, not just the case.

The E5EC-CC4A5M-014 carries an event input for remote run/hold or alarm reset, a feature not present on the base E5EC-CC4A5M-000 variant — if your panel uses a dry-contact for start interlock, this is the one.

Frequently asked questions

Does the E5EC-CC4A5M-014 support Modbus communication?

Yes — the RS-485 port supports Modbus and CompoWay/F protocols, so it integrates directly with most PLC and SCADA systems.

MPN