Omron E5EC series process and temperature controller, 24VAC/DC, PID control, analog + relay + voltage (external SSR) outputs, RS-485 CompoWay/F and Modbus, IP66 front panel, active.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

E5EC-CQ4D5M-009 specifications
ParameterValue
SeriesE5EC
Supply voltage24 VAC/DC
IP ratingIP66
ProtocolRS-485 (CompoWay/F, Modbus)
MountingPanel Mount
Temp operating max55 °C
Temp operating min-10 °C
Weight0.463 lb (210.01 g)
PackageBulk
Control methodOn/Off, Proportional (PID)

Product details

What this controller brings to the panel

The Omron E5EC-CQ4D5M-009 is a 1/16 DIN process and temperature controller that accepts RTD and a wide range of thermocouples (B, E, J, K, L, N, PLII, R, S, T, U, W) plus analog inputs of 0–20 mA or 0–10 VDC, covering the full span from -200°C to 2300°C. Its mixed output set — one analog channel, four relay outputs, and a voltage pulse for external SSR — means you can drive a heater directly through the SSR output, send a retransmission signal to a PLC or recorder via the analog output, and still have four relay contacts for alarms or on/off stages. The RS-485 port speaks both CompoWay/F and Modbus, so it drops into most existing fieldbus architectures without a protocol converter.

Control method and key features

Control method is selectable between on/off and proportional (PID), so it handles simple level control or tight temperature regulation depending on the loop. Built-in heater fault detection monitors current draw and flags a broken heater or SSR short — a useful diagnostic for electric furnaces, ovens, and extruder zones where an undetected heater failure ruins a batch. The event input accepts a dry-contact or solid-state signal to switch between preset sets of PID parameters, remote setpoint, or run/hold — handy for recipe changes without touching the front panel.

Panel mount with a rectangular cutout of 92.00 mm × 45.00 mm and screw terminals for field wiring. The front panel carries an IP66 rating, meaning it withstands hose-down and dust ingress; suitable for food-processing, washdown, or outdoor enclosures where the controller face is exposed.

MPN