Omron E5EC-TRR4D5M-008 Process / Temperature Controller, Series E5EC-T, 24 VAC/DC supply, 6 relay outputs, RS-485 Modbus, IP66 front panel, 92 x 45 mm panel cutout.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

E5EC-TRR4D5M-008 specifications
ParameterValue
SeriesE5EC-T
Output signalRelay (6)
Supply voltage24 VAC/DC
IP ratingIP66
ProtocolRS-485 (CompoWay/F, Modbus)
MountingPanel Mount
Temp operating max55 °C
Temp operating min-10 °C
Weight0.463 lb (210.01 g)
PackageBulk
Control methodOn/Off, Proportional (PID)

Product details

Panel fit and supply voltage decision

The E5EC-TRR4D5M-008 runs on 24 VAC/DC, which keeps the control transformer small and lets it share a 24 V rail with sensors and PLC I/O in the same enclosure. The rectangular panel cutout is 92.00 mm x 45.00 mm — the standard 1/4 DIN footprint for this class, so it drops into existing cutouts without rework. The front panel carries an IP66 rating — dust-tight and protected against hose-directed water. That matters for washdown zones in food, beverage, or chemical processing where a standard NEMA 4X front is expected.

Input flexibility and control loop

This controller accepts RTD and 13 thermocouple types (B, E, J, K, L, N, PLII, R, S, T, U, W) covering -200°C to 2300°C, plus 0–20 mA and 0–10 VDC process signals. That range spans everything from cryogenic storage to furnace exhaust, so one part number covers most sensor types on a line. Control method is On/Off or proportional (PID). The six relay outputs handle direct heater switching or alarm annunciation without external interposing relays for moderate loads. RS-485 communication supports both CompoWay/F and Modbus protocols. That lets the controller report setpoint, PV, and alarm status to a PLC or SCADA host over a standard two-wire bus without a protocol converter.

Heater fault detection and event input

Built-in heater fault detection monitors the load current and flags a broken heater or SSR short before the process drifts out of spec. The event input can trigger a preset value change or alarm mask from a dry contact — useful for recipe switching or manual override without touching the front panel.