The 640 mm protected height and 92 beams cover a vertical access opening. The 16 m maximum sensing range allows flexible machine layout. Response time is between 8 and 13 msec.
Environmental and compliance posture
Rated IP69K, the sensor withstands high-pressure, high-temperature washdown. Operating temperature range is -27 °F to 131 °F.
Both emitter and receiver terminate in open-ended cables, 15 m length on each side. That gives you enough lead to route through cable glands into the control cabinet without a junction box. The auxiliary output is configurable as NPN or PNP, 100 mA at 24V DC — useful for feeding a status lamp or PLC input to confirm the curtain is aligned and powered. No AC rating on this unit; it is strictly 24V DC, so verify your control voltage before terminating.