It guards against operator access to pinch points, cutting areas, or robot cells by emitting an array of synchronized infrared beams.
Deployment Context
As a safety light curtain, this unit is typically mounted at the entry point of a hazard zone, with the transmitter and receiver aligned across the opening. It connects into a safety-rated control circuit (SIL 3 / PL e class) via the OSSD outputs, and requires a reset circuit per ISO 13849-1. The package is Bulk, meaning it ships as a single unit without retail packaging — standard for OEM integration.