What the 25 mm detection capability means for your guarding zone
That 25 mm figure is the minimum object size the curtain reliably catches — a finger or tool thinner than that could slip past undetected, so this curtain is sized for hand-entry hazards, not finger-level resolution. The 22 beams at a 20 mm pitch give a 465 mm protective height, covering a reach zone up to that vertical span. Operating range runs from 0.2 m to 7.0 m, which covers most machine-loading and press-brake guarding distances without needing a secondary set.
Deployment context — where IP65 and blanking matter
Not rated for immersion or high-pressure spray (IP67/IP69K would be required for those). The blanking and muting functions let you teach out a fixed obstruction (a bracket or part chute) or bypass the curtain during a material feed cycle, which is common on assembly stations where a workpiece must pass through the field without stopping the machine. Both features are configured via the controller, not hard-wired.