Skip to main content
Omron G2R-1-SN AC110(S) — General Purpose Relays

Omron G2R-1-SN AC110(S) SPDT Relay, 110V AC Coil

MPNG2R-1-SN AC110(S)

Omron G2RS Series, General Purpose Relay, 110V AC, SPDT, 5 Pins, LED and Mechanical Flag Indicator.

$2.96Ref. price · indicative, final on quote
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

G2R-1-SN AC110(S) — Identification
ParameterValue
SeriesG2RS
G2R-1-SN AC110(S) — Contacts & Switching
ParameterValue
Contact formSPDT
Contact rating (AC)7.5 A @ 250V10 A @ 250V
Mechanical life (operations)10,000,000; 20,000,000
Electrical life (operations)100,000
G2R-1-SN AC110(S) — Coil & Supply
ParameterValue
Coil voltage110V AC
G2R-1-SN AC110(S) — Electrical
ParameterValue
Dielectric strength1,000V AC, 50/60 Hz for 1 min Between Contacts of Same Polarity; 5,000V AC, 50/60 Hz for 1 min Between Coil and Contacts
G2R-1-SN AC110(S) — Function & Indication
ParameterValue
Status indicatorLED and Mechanical Flag
Push-to-test buttonNo Test Button
G2R-1-SN AC110(S) — Mechanical
ParameterValue
Electrical connection typePin
Number of pins/terminals5
G2R-1-SN AC110(S) — Other specifications
ParameterValue
Contact rating5 A @ 30V10 A @ 30V

Product details

The Omron G2R-1-SN AC110(S) is a Series G2RS general-purpose relay with a 110V AC coil and SPDT contact form. It carries a 5-pin terminal layout and includes both an LED and mechanical flag status indicator for quick visual confirmation of coil state in a panel.

The relay is rated for AC switching at 7.5 A and 10 A at 250V AC, and DC switching at 5 A and 10 A at 30V DC. Electrical durability is rated at 100,000 operations. Mechanical durability is rated at 10,000,000 or 20,000,000 operations.

Dielectric Strength and Isolation

Dielectric strength is specified at 1,000V AC between contacts of the same polarity, and 5,000V AC between coil and contacts — both at 50/60 Hz for one minute. The 5 kV coil-to-contact isolation is the figure that matters for safety isolation in control panels; it ensures the coil circuit and switched circuit remain separated under fault conditions.

Frequently asked questions

What is the closest functional second-source to G2R-1-SN AC110(S)?

The closest peer in the same G2RS family is the G2R-2-SNDI DC24(S), but it has a 24V DC coil, DPDT contact form, and 8-pin layout — it will not drop into the same socket or circuit without rewiring.

What is the series and coil voltage of G2R-1-SN AC110(S)?

The G2R-1-SN AC110(S) belongs to the Omron G2RS series and has a 110V AC coil voltage.

MPN