Skip to main content
Omron G3PA-420B-VD — Solid State Relays

Omron G3PA-420B-VD SSR, 0.5-30 A, 180-440 VAC

MPNG3PA-420B-VD

Omron G3PA series solid state relay, order code G3PA-420B-VD, 0.5 to 30 A load current at 30°C, 180 to 440 VAC load voltage, 12 to 24 VDC input.

$140.00Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

G3PA-420B-VD — Specifications
ParameterValue
Depth100 mm
ModelG3PA-430B-VD
Width37 mm
Height100 mm
Load current0.5 to 30 A at 30°C
Voltage12 to 24 VDC
Inrush current220 A (60 Hz, 1 cycle)
Load voltage range180 to 440 VAC (50/60 Hz)
Rated load voltage200 to 400 VAC(50/60 Hz)
VDRM (reference value)1,000 V (VDRM)
Input current impedance7 mA max
Operating voltage range9.6 to 30 VDC
Voltage levelMust operate voltage9.2 VDC maxMust release voltage : 1 VDC min

Product details

What this SSR delivers

The Omron G3PA-420B-VD is a panel-mount solid state relay switching 0.5 to 30 A at 30°C across a load voltage range of 180 to 440 VAC (50/60 Hz). The 30 A figure is the thermal limit at 30°C ambient — derate for higher panel temperatures. Input side accepts 12 to 24 VDC (operating range 9.6 to 30 VDC) and draws 7 mA max, so it loads a PLC or controller output lightly. The 37 mm width and 100 mm depth fit a standard DIN-rail footprint, leaving room alongside contactors or terminal blocks in a control cabinet. Rated inrush of 220 A (60 Hz, 1 cycle) means it can handle the cold-filament surge of incandescent lamps or transformer primaries without immediate failure.

The 0.5 to 30 A load current at 30°C covers motor starters, heater banks, and lamp loads up to that thermal limit. The 180 to 440 VAC load voltage range suits three-phase systems at 200, 230, 400, or 415 VAC line-to-line. Input must-operate voltage is 9.2 VDC max; release voltage is 1 VDC min — so a 12 VDC or 24 VDC control signal is reliable, but a marginal 9 VDC supply may not hold it closed.

Frequently asked questions

Where can I buy the G3PA-420B-VD and get current pricing?

The G3PA-420B-VD is sourced and quoted to order against an RFQ through independent distribution. Current pricing and availability are confirmed at quote time — submit an RFQ for a firm quote.

What is the load current rating of the G3PA-420B-VD?

The G3PA-420B-VD switches 0.5 to 30 A at 30°C, with a load voltage range of 180 to 440 VAC (50/60 Hz). The 30 A figure is the thermal limit at 30°C ambient; derate for higher panel temperatures.

What input voltage does the G3PA-420B-VD require?

The input is rated 12 to 24 VDC, with an operating range of 9.6 to 30 VDC. It draws 7 mA max, so it loads a PLC or controller output lightly. Must-operate voltage is 9.2 VDC max; release voltage is 1 VDC min.

MPN
G3PA-420B-VD