Skip to main content
Omron G3PB-535B-2N-VD — Solid State Relays

Omron G3PB-535B-2N-VD Three-Phase SSR, 35 A, 480 VAC, DIN Ra

MPNG3PB-535B-2N-VD

Omron G3PB series three-phase solid state contactor, G3PB-535B-2N-VD, 35 A rated load, 200-480 VAC, DIN rail mount with built-in heat sink, screw terminals, zero-cross switching.

$161.00 – $425.48Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

G3PB-535B-2N-VD key specifications
ParameterValue
3-phase typeN = DIN track mounting and built-in heat sink
Product typeThree-phase Solid State Contactors
Terminal typeB = Screw terminals
Main circuit voltage200 to 480 VAC
Output ON voltage drop1.8 V (RMS) max.
Rated load power supply voltage5 = 480 VAC
Leakage current20 mA (at 480 VAC)
Rated load current35 = 35 A
Poles2
Applicable phases3
Single-phase/3-phase and number of elements for 3-phase2 = 3-phase, 2-element models
Applicable heater capacity (with class-1 AC resistive load)29.0 kW max. (35 A)

All specifications

G3PB-535B-2N-VD additional specifications
ParameterValue
Ambient temperature operating–30°C to 80°C (with no icing or condensation) Storage : –30°C to 100°C (with no icing or condensation)
Shock resistanceDestruction : 294 m/s2 (98 m/s2 with reverse mounting)
Vibration resistanceDestruction : 10 to 55 to 10 Hz, 0.175-mm single amplitude (Mounted to DIN track)
Ambient humidity operating45% to 85%
WeightApprox. 1.65 Kg
Shipping weight3 Kg
CertificationVD = Certified by UL, CSA, and VDE
Operate time1/2 of load power source cycle + 1 ms max. (DC input)
Release time1/2 of load power source cycle + 1 ms max. (DC input)
Basic model nameG3PB = Solid State Relay
Dielectric strength2,500 VAC, 50/60 Hz for 1 min
Estimated lead timeUsually ships in 1-10 working days.
Zero cross functionYes
Insulation resistance100 M? min. (at 500 VDC)

Product details

The G3PB-535B-2N-VD is a three-phase solid state contactor from Omron's G3PB series, rated for 35 A load current on a 200 to 480 VAC main circuit. It's built for switching resistive heater loads in industrial ovens, packaging seal bars, and process heating zones where mechanical contactor wear is a problem. The DIN track mounting and integrated heat sink (the 'N' suffix) mean it clips onto a standard rail and sheds heat without an external heatsink — saves panel space and one assembly step.

The 35 A rating is for a Class-1 AC resistive load (heater), which translates to 29.0 kW max at 480 VAC three-phase. That's the number to match against your heater bank nameplate — if the load draws 38 A steady-state, this unit is undersized. The 200-480 VAC range covers common global line voltages, but note it's a 2-element control scheme (switching two phases; the third passes through), which is standard for three-phase resistive loads. Leakage current sits at 20 mA at 480 VAC — enough to ghost a small pilot light if the load is high-impedance; factor that into your circuit design. The zero-cross function turns on at the voltage zero point, which minimizes inrush and RFI — good for heater loads but not for inductive loads like transformers, where random-switch SSRs are preferred.

Screw terminals (B-type) accept standard ring or fork lugs — no special crimp tool needed. The DIN rail mount (N-type) snaps onto a 35 mm rail; the built-in heat sink is sized for the 35 A rating, so no extra derating for enclosure height. Vibration resistance is 0.175-mm amplitude at 10-55 Hz when mounted to DIN rail — adequate for panel-mounted gear but not for direct machine mounting. Shock resistance is 294 m/s² (destruction), dropping to 98 m/s² if reverse-mounted; keep the orientation per the manual for full shock rating.

Frequently asked questions

What certifications does this SSR carry?

The 'VD' suffix indicates certification by UL, CSA, and VDE, covering North American and European regulatory requirements for industrial control equipment.

What is the maximum heater load this can switch?

At 480 VAC three-phase, it handles up to 29.0 kW of Class-1 AC resistive load (35 A). For other voltages, compute from the 35 A rating.

MPN
G3PB-535B-2N-VD