Skip to main content
Omron G9SX-AD322-T15-RC DC24 — Safety Relays

Omron G9SX-AD322-T15-RC DC24 Safety Controller, SIL3, 24VDC

MPNG9SX-AD322-T15-RC DC24
Active

Omron G9SX series safety controller, G9SX-AD322-T15-RC DC24, Category 4 / PLe / SIL3, 24VDC supply, 6 solid-state safety outputs, 2 digital inputs, 2 auxiliary solid-state outputs, delay 0–15 sec, DIN rail mount, spring terminals.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

G9SX-AD322-T15-RC DC24 — Mechanical
ParameterValue
Weight0.441 lb (200.03 g)
G9SX-AD322-T15-RC DC24 — Other specifications
ParameterValue
SeriesG9SX
FeaturesDelay Time 0 ~ 15sec, Logical AND I/O
MountingDIN Rail
Approval agencyCE, CSA, cULus, SUD, TUV, UL
Controller typeGeneral Purpose
Safety categoryCategory 4, PLe, SIL3
Supply voltage24VDC
Termination styleSpring Terminal
Operating temperature-10°C~55°C
Safety outputs and typeSolid State (6)
Number of inputs and type2 - Digital
Auxiliary outputs and typeSolid State (2)

Product details

The Omron G9SX-AD322-T15-RC DC24 is a general-purpose safety controller rated to Category 4, PLe, and SIL3. It runs on a 24VDC supply and packs six solid-state safety outputs plus two auxiliary solid-state outputs, with two digital inputs. The built-in delay timer adjusts from 0 to 15 seconds, and the logical AND I/O lets you cascade units without extra wiring.

SIL3 and Category 4 / PLe cover the highest safety integrity for machinery risk reduction — think emergency stops, light curtains, or two-hand controls on presses or robotic cells. The six solid-state safety outputs switch loads directly without external contactors for smaller applications, but watch the total current budget: solid-state outputs have a per-channel and package limit not listed here, so size your load accordingly. The two auxiliary outputs mirror status or fault signals to a PLC. The 0–15 second delay is adjustable on the unit itself — no software needed. That covers off-delay for guard door monitoring or timed restart inhibits. The logical AND I/O means you can daisy-chain multiple G9SX units so all inputs must be satisfied before outputs turn on, which simplifies wiring on multi-zone machines.

Spring-cage terminals accept 0.2–2.5 mm² solid or ferruled stranded wire — strip to 8 mm. The 24VDC supply is polarity-protected but not reverse-voltage protected; double-check polarity before powering.

Frequently asked questions

What safety integrity level does this controller meet?

It meets Category 4 per EN ISO 13849-1, PLe, and SIL3 per IEC 61508.

What is the supply voltage and how many outputs does it have?

It operates on 24VDC and provides six solid-state safety outputs plus two auxiliary solid-state outputs.

How is the delay time set?

The delay is adjustable from 0 to 15 seconds via a dial on the front of the unit — no programming tool required.

MPN