Skip to main content
Omron G9SX-AD322-T150-RC DC24 — Safety Relays

Omron G9SX-AD322-T150-RC DC24 Safety Controller, SIL3 PLe, 2

MPNG9SX-AD322-T150-RC DC24
Active

Omron G9SX series safety controller, G9SX-AD322-T150-RC DC24, 24VDC, Category 4 PLe SIL3, 6 solid-state safety outputs, 2 digital inputs, 0-150s delay, spring terminals, DIN rail mount.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

G9SX-AD322-T150-RC DC24 — Mechanical
ParameterValue
Weight0.441 lb (200.03 g)
G9SX-AD322-T150-RC DC24 — Other specifications
ParameterValue
SeriesG9SX
FeaturesDelay Time 0 ~ 150sec, Logical AND I/O
MountingDIN Rail
Approval agencyCE, CSA, cULus, SUD, TUV, UL
Controller typeGeneral Purpose
Safety categoryCategory 4, PLe, SIL3
Supply voltage24VDC
Termination styleSpring Terminal
Operating temperature-10°C~55°C
Safety outputs and typeSolid State (6)
Number of inputs and type2 - Digital
Auxiliary outputs and typeSolid State (2)

Product details

Safety controller with integrated delay and AND logic

The Omron G9SX-AD322-T150-RC DC24 is a general-purpose safety controller rated to Category 4, PLe, SIL3 — the highest performance level for safety circuits under ISO 13849 and IEC 62061. It provides six solid-state safety outputs and two auxiliary solid-state outputs, driven by two digital inputs, with a built-in delay timer adjustable from 0 to 150 seconds and logical AND I/O capability.

The SIL3 / PLe / Cat.4 rating means this unit can be used in safety functions up to the highest risk-reduction level — think emergency-stop circuits, light curtains, or two-hand controls on presses. The six solid-state safety outputs are internally monitored for cross faults and short circuits; the two auxiliary outputs are also solid-state but not safety-rated — they can drive a PLC input or indicator lamp. The 0-150 s delay is configurable via a front-panel potentiometer, useful for muting or delayed restart sequences. Supply is 24 VDC nominal; spring terminals speed wiring and eliminate screw-torque checks. Approvals include CE, CSA, cULus, SUD, TUV, and UL — covers most global panel certifications without extra paperwork.

Integration notes

Spring terminals accept 0.2–2.5 mm² solid or ferruled stranded wire; strip length 8 mm. The delay timer is set by a rotary switch on the front — no software needed. Logical AND I/O means you can cascade multiple G9SX units for expanded input count or muting logic without an external PLC. The six safety outputs are solid-state (PNP, 24 VDC, 0.5 A each typical) — verify load type; they do not switch AC or high DC currents. The two auxiliary outputs are also solid-state, 0.5 A each, and share the same supply rail.

Frequently asked questions

What safety level does this controller achieve?

It is rated Category 4, PLe, SIL3 — the highest performance level under ISO 13849 and IEC 62061. This covers emergency stop, light curtain, and two-hand control applications.

What is the delay range and how is it set?

The delay timer is adjustable from 0 to 150 seconds. It is set via a front-panel rotary switch — no programming software required.

What approvals does it carry?

CE, CSA, cULus, SUD, TUV, and UL. These cover most global panel certification requirements.

MPN
G9SX-AD322-T150-RC DC24