Skip to main content
Omron G9SX-ADA222-T15-RC — Safety Relays

Omron G9SX-ADA222-T15-RC Flexible Safety Unit, 24 VDC, 15 s

MPNG9SX-ADA222-T15-RC

Omron G9SX-ADA222-T15-RC Flexible Safety Unit, Advanced Unit, 24 VDC, 15 s max OFF-delay, 2 instantaneous + 2 OFF-delayed safety outputs, 2 auxiliary PNP outputs, spring-cage terminals.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

G9SX-ADA222-T15-RC — Mechanical
ParameterValue
Weight0.2 kg

Product details

Safety unit with configurable OFF-delay

The Omron G9SX-ADA222-T15-RC is a Flexible Safety Unit from the Advanced ADA series, designed for applications needing a timed safe stop. It operates on a 24 VDC supply with a tolerance of −15% to 10% of rated voltage, so it holds through dips down to 20.4 VDC and rides through surges to 26.4 VDC. The unit provides two instantaneous safety outputs and two OFF-delayed safety outputs, each rated for 1 A DC when using two or fewer outputs, derating to 0.8 A DC when all three or more are loaded. This is a P-channel MOS FET transistor output — solid-state, not relay contacts — so it switches quietly and lasts longer in high-cycle applications. The OFF-delay is factory-set to a maximum of 15 seconds, which covers common machine-guarding scenarios like a press brake or robot cell where the hazardous motion must stop within a timed window after the guard opens.

Termination and mounting

This is a time-saver on the panel build and eliminates the risk of a loosened screw under vibration.

Frequently asked questions

What is the maximum load current on the safety outputs?

Each safety output is rated for 1 A DC maximum when using two or fewer outputs, and 0.8 A DC maximum when using three or more outputs. This is a P-channel MOS FET transistor output.

What is the OFF-delay time on this unit?

The maximum OFF-delay time is 15 seconds. The unit provides two OFF-delayed safety outputs and two instantaneous safety outputs.

What type of terminals does the G9SX-ADA222-T15-RC use?

It uses spring-cage terminals (RC suffix), which accept solid or ferruled stranded wire without screw clamping.

MPN
G9SX-ADA222-T15-RC