Skip to main content
Omron G9SX-ADA222-T150-RC — Safety Relays

Omron G9SX-ADA222-T150-RC Flexible Safety Unit, 24 VDC, 150

MPNG9SX-ADA222-T150-RC

Omron G9SX-ADA222-T150-RC, Flexible Safety Unit, Advanced Unit, 24 VDC, 2 instantaneous + 2 OFF-delayed safety outputs, 150 s max OFF-delay, spring-cage terminals.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

G9SX-ADA222-T150-RC key specifications
ParameterValue
Product typeFlexible Safety Unit
RC - terminal block typeSpring-cage terminals
Rated supply voltage24 VDC
Operating voltage range−15% to 10% of rated supply voltage
Load current100 mA max.
Rated power consumption4 W max.
Vibration resistanceFrequency: 10 to 55 to 10 Hz, 0.375-mm single amplitude (0.75-mm double amplitude)
Weight0.2 kg
Shipping weight1.5 kg
ManufacturerOmron
Safety inputOperating voltage: 20.4 VDC to 26.4 VDC, internal impedance: approx. 2.8 k?
ADA - functionsAdvanced Unit

All specifications

G9SX-ADA222-T150-RC additional specifications
ParameterValue
Auxiliary outputPNP transistor outputLoad current: 100 mA max.
Estimated lead time1 - 10 Working days
Using 2 outputs or less1 A DC max.
Using 3 outputs or more0.8 A DC max.
T150 - max. OFF-delay time150 s
2 - output configuration (Auxiliary outputs)2 outputs
2 - output configuration (OFF-delayed safety outputs)2 outputs
Instantaneous safety output OFF-delayed safety outputP channel MOS FET transistor outputLoad current:Using 2 outputs or less: 1 A DC max.Using 3 outputs or more: 0.8 A DC max.
2 - output configuration (Instantaneous safety outputs)2 outputs

Product details

The Omron G9SX-ADA222-T150-RC is a Flexible Safety Unit from the ADA series, built for configurable machine safety logic with up to 150 seconds of OFF-delay. It runs on a 24 VDC supply with a −15% to 10% tolerance, drawing 4 W max. The unit packs two instantaneous safety outputs and two OFF-delayed safety outputs, each rated 1 A DC when using two or fewer outputs, derating to 0.8 A DC with three or more active. The 150-second OFF-delay is set via the T150 suffix — a long window for timed safe shutdown of sliding gates, press brakes, or conveyor zones where motion must coast to a stop before the guard unlocks. Spring-cage terminals (RC suffix) speed wiring and hold up to vibration per the 10–55 Hz, 0.375-mm amplitude test.

Frequently asked questions

What is the maximum OFF-delay time?

The maximum OFF-delay time is 150 seconds, set by the T150 suffix. This is a fixed maximum — the unit is configured for that delay range.

What are the safety output current ratings?

When using two or fewer safety outputs, each is rated 1 A DC max. When using three or more outputs, the rating derates to 0.8 A DC max per output.

Does this unit have auxiliary outputs?

Yes, it has two auxiliary PNP transistor outputs, each rated 100 mA max. These are typically used for status feedback to a PLC or indicator lamps.

What type of terminals does it use?

Spring-cage terminals (RC suffix). They accept solid or ferruled stranded wire and provide vibration-resistant connections.

MPN
G9SX-ADA222-T150-RC