Skip to main content
Omron H3CR-H8RL AC/DC24 M — Electronic Timers & Counters

Omron H3CR-H8RL AC/DC24 M Timer, Off-Delay, 12 Min, SPDT

MPNH3CR-H8RL AC/DC24 M
Active

Omron H3CR-H series H3CR-H8RL AC/DC24 M, mechanical-relay off-delay timer, SPDT (1 Form C), 5 A at 250 VAC, 0.05 to 12 min range, 24 VAC/DC supply, 8-pin octal plug-in, hand-dial adjustment.

$109.50 – $137.89Ref. price · indicative, final on quote
StockContact for availability
Lead timeIn Stock wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

H3CR-H8RL AC/DC24 M — Identification
ParameterValue
SeriesH3CR-H

Function & Modes

H3CR-H8RL AC/DC24 M — Function & Modes
ParameterValue
FunctionOff-Delay

Timing & Counting

H3CR-H8RL AC/DC24 M — Timing & Counting
ParameterValue
Delay time range0.05 Min ~ 12 Min
Timing adjustment methodHand Dial
Timing initiate methodInput Voltage

Electrical

H3CR-H8RL AC/DC24 M — Electrical
ParameterValue
Supply voltage24VAC/DC

I/O & Contacts

H3CR-H8RL AC/DC24 M — I/O & Contacts
ParameterValue
Contact rating @ voltage5A @ 250VAC
Contact circuit (Form)SPDT (1 Form C)
Relay typeMechanical Relay

Mechanical

H3CR-H8RL AC/DC24 M — Mechanical
ParameterValue
Mounting typeSocketable
Termination stylePlug In, 8 Pin (Octal)

Product details

Off-delay timing block for control panels

The Omron H3CR-H8RL AC/DC24 M is an 8-pin octal plug-in off-delay timer in the H3CR-H series: power is applied to start the timing cycle and the SPDT (1 Form C) contact transfers immediately, then drops out after the dial-set interval once supply is removed, making it the natural pick for cool-down, post-purge, and load-discharge sequences in motor and heater control circuits. Delay range is 0.05 min to 12 min on a hand-dial adjustment — a wide enough span to cover short-cycle fan rundown timers and longer duct-fan or compressor bleed-off duties from a single SKU, so the panel builder does not stock separate ranges for each application.

Contact and supply ratings

Output is a mechanical relay, SPDT, rated 5 A at 250 VAC — enough headroom for small contactor coils, solenoid valves, and indicator loads without an interposing relay, but a panel-side fuse or breaker sized below the contact rating remains the right pattern for downstream short-circuit protection. Supply is 24 VAC/DC, so the same unit feeds from a 24 VDC PLC rail or a 24 VAC control transformer without a separate power supply — convenient for retrofit work where the existing control voltage is mixed.

Mounting and socket wiring

Socketable mounting on an 8-pin octal base means the timer plugs into the same round-pin sockets commonly used for control relays — swap-out during commissioning or a fault-finding cycle is a pull-and-replace, not a rewire, which shortens mean-time-to-repair on lines where the timer sits in the field.

MPN
H3CR-H8RL AC/DC24 M