Omron H3CR-H8RL AC200-240 S — Electronic Timers & Counters

Omron H3CR-H8RL AC200-240 S Time Delay Relay, Off-Delay, 0.0

MPNH3CR-H8RL AC200-240 S
Active

Omron H3CR-H series, off-delay time relay, SPDT (1 Form C), 0.05 s to 12 s delay, 200–240 VAC supply, 5 A @ 250 VAC contact rating, socketable octal 8-pin plug-in.

$139.54Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

H3CR-H8RL AC200-240 S — Identification
ParameterValue
SeriesH3CR-H
H3CR-H8RL AC200-240 S — Function & Modes
ParameterValue
FunctionOff-Delay
H3CR-H8RL AC200-240 S — Timing & Counting
ParameterValue
Delay time range0.05 Sec ~ 12 Sec
Timing adjustment methodHand Dial
Timing initiate methodInput Voltage
H3CR-H8RL AC200-240 S — Electrical
ParameterValue
Supply voltage200 ~ 240VAC
H3CR-H8RL AC200-240 S — I/O & Contacts
ParameterValue
Contact rating @ voltage5A @ 250VAC
Contact circuit (Form)SPDT (1 Form C)
Relay typeMechanical Relay
H3CR-H8RL AC200-240 S — Mechanical
ParameterValue
Mounting typeSocketable
Termination stylePlug In, 8 Pin (Octal)

Product details

Off-delay timer, octal base, 0.05–12 s range

The Omron H3CR-H8RL AC200-240 S is a socket-mount off-delay timer relay in the H3CR-H series. It switches a single SPDT (1 Form C) load up to 5 A at 250 VAC, with the delay set by a front-panel hand dial from 0.05 s to 12 s. Supply is 200–240 VAC, terminated via an 8-pin octal plug-in base.

The off-delay function means the timer starts counting when power is removed — the output relay stays energized during the delay, then drops out. This is the standard timing mode for staging fan coast-down, conveyor brake sequencing, or transformer inrush suppression after a power loss. The 0.05 s to 12 s range covers short dwells for anti-short-cycle protection up to moderate post-run delays. The 5 A @ 250 VAC contact rating is sufficient for pilot-duty control circuits or small contactor coils; for higher thrush loads, interpose a larger contactor.

Frequently asked questions

What is the delay range and timing method on this relay?

The delay is adjustable from 0.05 s to 12 s via a front-panel hand dial. The timing initiate method is input voltage — the off-delay cycle starts when supply is removed.

What is the contact configuration and rating?

SPDT (1 Form C) rated 5 A at 250 VAC. Enough for pilot-duty control or small contactor coils.

Where can I buy H3CR-H8RL AC200-240 S and get current pricing?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time.