Skip to main content
Omron H3CR-HRL DC48 M — Electronic Timers & Counters

Omron H3CR-HRL DC48 M Time Delay Relay, Off-Delay, 48 VDC, 0

MPNH3CR-HRL DC48 M
Active

Omron H3CR-H series, off-delay timer relay, DPDT (2 Form C), 48 VDC supply, adjustable 0.05-12 min, 5A @ 250VAC contact rating, socketable 11-pin octal base.

$150.36Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

H3CR-HRL DC48 M — Identification
ParameterValue
SeriesH3CR-H
H3CR-HRL DC48 M — Function & Modes
ParameterValue
FunctionOff-Delay
H3CR-HRL DC48 M — Timing & Counting
ParameterValue
Delay time range0.05 Min ~ 12 Min
Timing adjustment methodHand Dial
Timing initiate methodInput Voltage
H3CR-HRL DC48 M — Electrical
ParameterValue
Supply voltage48VDC
H3CR-HRL DC48 M — I/O & Contacts
ParameterValue
Contact rating @ voltage5A @ 250VAC
Contact circuit (Form)DPDT (2 Form C)
Relay typeMechanical Relay
H3CR-HRL DC48 M — Mechanical
ParameterValue
Mounting typeSocketable
Termination stylePlug In, 11 Pin (Octal)

Product details

Off-delay timer, socketable, 48 VDC

The Omron H3CR-HRL DC48 M is an off-delay timer relay from the H3CR-H series. It switches a DPDT (2 Form C) load rated 5A at 250VAC, with the delay adjustable by hand dial from 0.05 to 12 minutes. The timing cycle starts when input voltage (48 VDC) is removed — typical for staging equipment shutdown or sequenced vent dampers.

Socketable octal base — field swap in seconds

Mounts on an 11-pin octal socket (plug-in style), so a failed unit pulls out and a replacement clicks in without breaking control wiring. The mechanical relay inside is serviceable on the bench, and the hand-dial adjustment means no programming tool is needed to set the delay.

Frequently asked questions

What is the H3CR-HRL DC48 M used for?

It is an off-delay timer relay: when power is removed from the 48 VDC coil, the relay contacts remain in their timed state for the set delay (0.05 to 12 minutes) before dropping out. Common in sequenced shutdowns, fan purge timers, or staging delays in industrial control panels.

How do I get pricing and availability for the H3CR-HRL DC48 M?

Submit an RFQ through this listing. The part is sourced to order through independent distribution; current pricing and lead time are confirmed at quote time.

What is the contact rating and circuit configuration?

DPDT (2 Form C) contacts rated 5A at 250VAC.

MPN
H3CR-HRL DC48 M