Skip to main content
Omron H3Y-2 AC200-230 10S — Electronic Timers & Counters

Omron H3Y-2 AC200-230 10S Timer Relay, DPDT, 10 s

MPNH3Y-2 AC200-230 10S
Active

Omron H3Y series electromechanical time-delay relay, DPDT (2 Form C), 5 A at 250 VAC, 0.5–10 s delay range, 200–230 VAC supply, plug-in socketable mount, bulk.

$31.50Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

H3Y-2 AC200-230 10S — Identification
ParameterValue
SeriesH3Y
H3Y-2 AC200-230 10S — Function & Modes
ParameterValue
FunctionOff-Delay, On-Delay
H3Y-2 AC200-230 10S — Timing & Counting
ParameterValue
Delay time range0.5 Sec ~ 10 Sec
Timing adjustment methodHand Dial
Timing initiate methodInput Voltage
H3Y-2 AC200-230 10S — Electrical
ParameterValue
Supply voltage200 ~ 230VAC
H3Y-2 AC200-230 10S — I/O & Contacts
ParameterValue
Contact rating @ voltage5A @ 250VAC
Contact circuit (Form)DPDT (2 Form C)
Relay typeMechanical Relay
H3Y-2 AC200-230 10S — Mechanical
ParameterValue
Mounting typeSocketable
Termination stylePlug In

Product details

0.5–10 s hand-dial, on-delay or off-delay in one socket

The H3Y-2 AC200-230 10S is Omron's H3Y series electromechanical time-delay relay built around a DPDT (2 Form C) mechanical relay contact set, with the delay adjustable from 0.5 Sec to 10 Sec on the front-face hand dial and the same unit capable of either off-delay or on-delay timing on application choice. That 10-second upper window makes the part the typical fit for short-cycle sequencing on packaging and machine-tool control panels — interlock delays, lubrication or pneumatic purge timers, and pump no-flow watchdogs — where a one-second-grade electronic timer would be over-specified and a motor-driven cam timer would be over-built.

Coil and contact ratings for control-panel service

The supply input is 200 ~ 230VAC and the timing initiate method is input voltage, so the timer is wired directly across the control transformer secondary with no separate DC rail — the relay closes or opens at the end of the dial-set interval based on whether on-delay or off-delay is selected. The DPDT contact set is rated 5A at 250VAC, which is the usual ceiling for switching small contactor coils, solenoid valves, and indicator lamps inside a control panel; the contact rating, not the supply voltage, is what governs how much load the timer can directly commutate and whether an interposing relay is needed downstream.

Plug-in 11-pin socket and panel footprint

Mounting is socketable with a Plug In termination, the standard H3Y form-factor that drops into an 11-pin octal base already on the DIN rail of an existing panel — the swap is a pull-and-replace on the base, not a rewire, which keeps retrofits on the H3Y line low-risk for panel builders standardising on that footprint.

Lifecycle read for the maintenance spare

Omron lists the H3Y-2 AC200-230 10S as active in catalog and a mature product line, meaning the part is still factory-current and supported for production runs while older variants in the series have been pruned — for a maintenance buyer that translates to a quoted-to-order supply posture from independent distribution with no last-time-buy urgency on this specific code.

Frequently asked questions

What is the closest substitute for H3Y-2 AC200-230 10S?

No official second-source or pin-compatible successor is recorded for this exact order code; the H3Y series itself remains the form-fit-function family, and other dial-set electromechanical timers in the same 11-pin socket footprint are qualitatively compatible but should be confirmed against the panel schematic before substitution.

MPN
H3Y-2 AC200-230 10S