Skip to main content
Omron H3Y-2 DC24 60M — Electronic Timers & Counters

Omron H3Y-2 DC24 60M Time Delay Relay, 24VDC, 2-60 Min, DPDT

MPNH3Y-2 DC24 60M
Active

Omron H3Y Series, Time Delay Relay, DPDT (2 Form C), 24VDC, 2 Min ~ 60 Min, 5A @ 250VAC, Socketable, Plug In.

$139.54Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

H3Y-2 DC24 60M — Identification
ParameterValue
SeriesH3Y
H3Y-2 DC24 60M — Function & Modes
ParameterValue
FunctionOff-Delay, On-Delay
H3Y-2 DC24 60M — Timing & Counting
ParameterValue
Delay time range2 Min ~ 60 Min
Timing adjustment methodHand Dial
Timing initiate methodInput Voltage
H3Y-2 DC24 60M — Electrical
ParameterValue
Supply voltage24VDC
H3Y-2 DC24 60M — I/O & Contacts
ParameterValue
Contact rating @ voltage5A @ 250VAC
Contact circuit (Form)DPDT (2 Form C)
Relay typeMechanical Relay
H3Y-2 DC24 60M — Mechanical
ParameterValue
Mounting typeSocketable
Termination stylePlug In

Product details

The Omron H3Y-2 DC24 60M is a socket-mount time delay relay from the H3Y series, running on 24 VDC and offering a hand-dial-adjustable delay window from 2 minutes to 60 minutes. The DPDT (2 Form C) output contacts are rated for 5 A at 250 VAC, which covers pilot duty, small motor starters, and signal-level switching in control panels. Both off-delay and on-delay functions are selectable on the same unit, giving the panel builder one part number for either timing mode.

The relay is socketable — it plugs into a standard 8-pin or 11-pin octal-style base (sold separately). The termination style is plug-in, so the relay body can be swapped without disturbing panel wiring. The 24 VDC coil is the timing initiate method: applying input voltage starts the timing cycle, and removing it resets the internal circuit. The hand dial on the face sets the delay period within the 2-to-60-minute range; no programming tool or potentiometer is required.

The mechanical relay type means the output is a physical contact closure — no solid-state leakage, and the 5 A rating at 250 VAC is the resistive load curve. For inductive loads like contactor coils or small solenoids, derate per the manufacturer's curve or add a snubber across the load. The package is bulk, so individual units arrive in standard anti-static or cardboard packaging, not tape-and-reel.

Frequently asked questions

What is the delay time range and how is it set?

The delay is adjustable from 2 minutes to 60 minutes via a hand dial on the relay face. No external resistor or programming device is needed — turn the dial to the desired time within that window.

What contact configuration and rating does this relay have?

It provides DPDT (2 Form C) contacts — two independent form-C changeover sets — rated at 5 A at 250 VAC. That covers most pilot-duty and signal-level switching in 120 VAC and 240 VAC control circuits.

Where can I buy the H3Y-2 DC24 60M and get current pricing?

This part is sourced to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit a request for quotation to receive a firm price and lead time.

MPN
H3Y-2 DC24 60M