Skip to main content
Omron H3YN-4 DC100-110 — Electronic Timers & Counters

Omron H3YN-4 DC100-110 Timer, 4PDT, 100-110VDC, 10 Min

MPNH3YN-4 DC100-110
Active

Omron H3YN series H3YN-4 DC100-110 multi-function timer relay, 4PDT (4 Form C), 100 ~ 110VDC coil, 0.1 Sec ~ 10 Min delay, 3A @ 250VAC contact, plug-in socket mount.

$105.37Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

H3YN-4 DC100-110 — Identification
ParameterValue
SeriesH3YN
H3YN-4 DC100-110 — Function & Modes
ParameterValue
FunctionProgrammable (Multi-Function)
H3YN-4 DC100-110 — Timing & Counting
ParameterValue
Delay time range0.1 Sec ~ 10 Min
Timing adjustment methodHand Dial
Timing initiate methodInput Voltage
H3YN-4 DC100-110 — Electrical
ParameterValue
Supply voltage100 ~ 110VDC
H3YN-4 DC100-110 — I/O & Contacts
ParameterValue
Contact rating @ voltage3A @ 250VAC
Contact circuit (Form)4PDT (4 Form C)
Relay typeMechanical Relay
H3YN-4 DC100-110 — Mechanical
ParameterValue
Mounting typeSocketable
Termination stylePlug In

Product details

Form-fit on the DIN rail

The Omron H3YN-4 DC100-110 is a plug-in, socketable timer relay from the H3YN series with a 4PDT (4 Form C) contact set, so four independent circuits can be timed from a single device — useful where a sequence needs more than one dry-contact output without stacking auxiliary relays. Supply is 100 ~ 110VDC and the unit terminates via 11-pin plug-in octal-style base, which keeps replacement a pull-and-swap on the socket rather than a re-wire.

Timing range and contact duty

Delay time spans 0.1 Sec ~ 10 Min across the dial, with timing initiated by input voltage and adjusted via the hand dial — the multi-function programmable mode means on-delay, interval, cycle, and other standard patterns are selected by the front-face switch rather than buying separate SKU variants. Contact rating is 3A @ 250VAC on a mechanical relay — adequate for control-circuit pilot duty to contactors, solenoid valves, and indicator loads, but the 3A ceiling means it will not drive a motor contactor coil bank directly on heavy inductive loads; stage through an interposing relay where the inrush is significant.

Frequently asked questions

What is H3YN-4 DC100-110's listed circuit configuration?

The contact set is 4PDT (4 Form C) — four pole, double throw — giving four independent timed changeover outputs from one timer body.

MPN
H3YN-4 DC100-110