Skip to main content
Omron J7KCR-12-10 DC60 — Contactors

J7KCR-12-10 DC60 Contactor, 5-15A, 51-56 VDC Coil

MPNJ7KCR-12-10 DC60

J7KCR-12-10 DC60, magnetic contactor, 5-15A max load current, 51-56 VDC coil, SPST-1N0 auxiliary contact, 200-400 VAC rated load voltage.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

J7KCR-12-10 DC60 — Specifications
ParameterValue
Max load current5-15A
Auxiliary contactSPST-1N0
Input voltage range51-56 VDC
Max rated load voltage200-400 VAC
Max operating input voltage51-56 VDC

Product details

The J7KCR-12-10 DC60 is a magnetic contactor for on/off motor control, rated for a max load current of 5-15A and a max rated load voltage of 200-400 VAC. The coil operates on a 51-56 VDC input, making it suitable for DC control circuits common in industrial panels where a separate 24 VDC supply is not available or where a higher DC rail is used for contactor holding.

The 5-15A max load current range covers small motor loads up to about 7.5 kW at 400 VAC (assuming AC-3 duty), so it fits fractional-horsepower pumps, fans, and conveyor drives. The SPST-1N0 auxiliary contact provides a single normally-open feedback signal for PLC status monitoring or interlocking. The 51-56 VDC coil voltage is a tight tolerance window — ensure your control supply delivers at least 51 VDC at the coil terminals under load, factoring in voltage drop across long cable runs or suppression diodes.

Panel Integration

Snap-on DIN rail mounting is standard for this form factor. The contactor occupies a single 45 mm module width, so it fits in a standard 600 mm enclosure with room for a motor-protective circuit breaker and a control transformer on the same rail. Wire the coil from a 48 VDC or 60 VDC supply; the 51-56 VDC range means a 48 V nominal supply may drop below the minimum under load, so size the transformer or DC supply for at least 56 VDC at the contactor terminals.

Frequently asked questions

Where can I buy the J7KCR-12-10 DC60 and get a price?

This part is sourced to order against an RFQ through independent distribution. Submit an RFQ for current availability and pricing; stock and lead time are confirmed at quote time.

What is the max load current rating of the J7KCR-12-10 DC60?

The max load current is rated at 5-15A, covering small motor loads up to approximately 7.5 kW at 400 VAC in AC-3 duty.

What coil voltage does the J7KCR-12-10 DC60 require?

The coil operates on a 51-56 VDC input. Ensure your control supply delivers at least 51 VDC at the coil terminals under load.

MPN
J7KCR-12-10 DC60