Omron K3HB-RNB-C2 — Process / Temperature Controllers

Omron K3HB-RNB-C2 Rotary Pulse Indicator, Relay Output, Matu

MPNK3HB-RNB-C2

Omron K3HB-R series, Rotary Pulse Indicator, K3HB-RNB-C2, NPN/voltage pulse input, relay output (HH/H/LL/L: SPST-NO each), 100-240 VAC / 24 VAC/VDC / DeviceNet 24 VDC supply, Approx. 300 g.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

K3HB-RNB-C2 — Specifications
ParameterValue
K3HB-RRotary Pulse Indicator
WeightApprox. 300 g
Altitude2,000 m max.
Supply voltage100 to 240 VAC, 24 VAC/VDC, DeviceNet power supply: 24 VDC
Input sensor codesNB = NPN input/voltage pulse input
Storage temperature−25 to 65°C (with no icing or condensation)
Ambient operating humidity25% to 85%
Ambient operating temperature−10 to 55°C (with no icing or condensation)
Relay (Transistor output type codes)C2 = Relay contact (HH/H/LL/L: SPST-NO each)

Product details

The Omron K3HB-RNB-C2 is a Rotary Pulse Indicator from the K3HB-R series, a digital panel indicator that reads pulse inputs from rotary encoders or similar NPN/voltage pulse sources and displays the count or rate on its front panel. The C2 output code means it comes with four SPST-NO relay contacts (HH, H, LL, L), each independently set for high/low alarm thresholds. Power supply flexibility is built in: it accepts 100 to 240 VAC, 24 VAC/VDC, or 24 VDC via a DeviceNet power supply connection, so it fits into both line-voltage and 24 VDC control circuits without an external converter.

The K3HB-RNB-C2 is a fast mover for panel builders and MRO stockrooms that standardize on the K3HB-R series for rate and count display. Keep one on the shelf if your line uses NPN pulse outputs and needs four relay setpoints — the min/max level is one unit per panel or two for critical spares.

The NB input code means it is wired for NPN open-collector or voltage pulse inputs — common for incremental rotary encoders and flow meters. If your sensor is PNP, you would need the PB input variant; this one expects the signal to sink to common. The four relay outputs (HH/H/LL/L) are each SPST-NO, rated for general-purpose switching of alarms, counters, or small pilot loads. They are not intended for direct motor or solenoid switching without an interposing contactor — treat them as signal-level outputs to a PLC or relay bank. Ambient operating temperature spans −10 to 55°C with 25% to 85% humidity, and storage goes to −25 to 65°C.

Frequently asked questions

What power supply options does it accept?

It accepts 100 to 240 VAC, 24 VAC/VDC, or 24 VDC via a DeviceNet power supply input. This covers both line-voltage panels and 24 VDC control systems.

What type of input sensor does it work with?

The NB code means it accepts NPN open-collector or voltage pulse inputs. It is not compatible with PNP sensors without a signal converter.

What are the relay output configurations?

The C2 output code provides four SPST-NO relay contacts labeled HH, H, LL, and L, each independently adjustable for high/low alarm setpoints.