Skip to main content
Omron K3MA-J-A2 AC100-240V — Process / Temperature Controllers

OMRON K3MA-J-A2 AC100-240V Digital Panel Meter, 5 Digits, 10

MPNK3MA-J-A2 AC100-240V

OMRON K3MA-J-A2 AC100-240V, Digital Panel Meter, 5 digits, 100 … 240 VAC 50/60 Hz supply, dual N.O. output contacts.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

K3MA-J-A2 AC100-240V — Identification
ParameterValue
TypeDigital Panel Meter
K3MA-J-A2 AC100-240V — Environmental
ParameterValue
Operating temperature-10 … 55°C
K3MA-J-A2 AC100-240V — Other specifications
ParameterValue
ModelK3MA-J-A2 AC100-240V
Digits5 Digits
Weight0,3 kg
Contacts2 Normally open
ConditionNew
Shelf no.240405
Supply voltage100 … 240,50 … 60 Hz
Type of productDigital Panel Meter
Power consumption6 VA
A (D conversion method)Double integral method
Current measurement input range0 … 20 mA,4 … 20 mA
Voltage measurement input range0-5 V,1-5 V, ± 5V, ±10V

Product details

What this panel meter does

The OMRON K3MA-J-A2 AC100-240V is a 5-digit digital panel meter built for reading process signals on a machine or line. It accepts both current loops — 0 to 20 mA and 4 to 20 mA — and voltage inputs spanning 0-5 V, 1-5 V, ±5 V, and ±10 V, so it covers the common transmitter outputs you'll find on pressure, temperature, and flow sensors out here in the grease. The dual normally-open contacts give you two independent setpoint outputs for alarming or basic on/off control, which saves wiring a separate limit controller for simple monitoring tasks.

Power and environment

Powered from 100 to 240 VAC at 50/60 Hz, drawing 6 VA — a standard control-transformer tap, no special supply needed. The operating range of -10 to 55 °C means it'll sit fine inside a ventilated panel next to a warm power supply, but don't bolt it right above a heater or a hot bearing housing. The A/D conversion uses a double-integral method, which is inherently good at rejecting 50/60 Hz line noise — a practical choice when the meter shares a panel with contactors and drives.

Frequently asked questions

What input signals does this meter accept?

It accepts 0 to 20 mA and 4 to 20 mA current inputs, plus voltage inputs of 0-5 V, 1-5 V, ±5 V, and ±10 V. This covers the standard 4-20 mA loop from most two-wire transmitters and the 0-10 V output from many pressure and temperature sensors.

What power supply does it need?

It runs on 100 to 240 VAC at 50 or 60 Hz, consuming 6 VA. A standard control transformer or line voltage tap will power it without needing a separate DC supply.

Does it have alarm outputs?

Yes, it has two normally-open contacts for setpoint alarming or basic on/off control. You can wire these to a PLC input, a horn, or a pilot light for high/low limit annunciation.

MPN