Skip to main content
Omron K3MA-L 100-240VAC — Process / Temperature Controllers

Omron K3MA-L 100-240VAC Temperature Meter, Panel Mount, -200

MPNK3MA-L 100-240VAC
Active

Omron K3MA-L series, Temperature Meter, panel mount, 100-240 VAC supply, RTD/thermocouple input, -200 to 1800°C range, IP66 front, LCD dual-color backlit display.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

K3MA-L 100-240VAC — Identification
ParameterValue
SeriesK3MA-L
TypeTemperature Meter
K3MA-L 100-240VAC — Electrical
ParameterValue
Supply voltage100 ~ 240VAC
K3MA-L 100-240VAC — Display
ParameterValue
Display typeLCD - Dual Color Characters, Backlight
Characters per row4
Character height0.560" (14.20mm)
K3MA-L 100-240VAC — Environmental
ParameterValue
Operating temperature-10°C ~ 55°C
Ingress protection (IP rating)IP66 - Dust Tight, Water Resistant
K3MA-L 100-240VAC — Mechanical
ParameterValue
Mounting typePanel Mount
Panel cutout dimensionsRectangular - 92.00mm x 45.00mm
Termination styleScrew Terminal
K3MA-L 100-240VAC — Other specifications
ParameterValue
Weight0.441 lb (200.03 g)
Measuring typeRTD, Thermocouple
Measuring range-200°C ~ 1800°C

Product details

Panel-mount temperature indicator for RTD and thermocouple inputs

The Omron K3MA-L 100-240VAC is a panel-mount temperature meter that accepts RTD or thermocouple inputs and displays the measured value on a dual-color backlit LCD. It covers a wide range from -200°C to 1800°C, making it suitable for most industrial process temperature monitoring applications — furnace zones, oven chambers, or pipe surface temps. Power it directly from a 100 to 240 VAC supply — no external step-down transformer needed for standard line voltages. The screw-terminal connection on the rear keeps wiring straightforward for a panel builder. The IP66-rated front face handles washdown environments and dusty panels, provided the gasket is seated correctly against the panel cutout. The rectangular cutout is 92.00 mm by 45.00 mm, a common size that retrofits into existing 1/8 DIN panel openings.

Frequently asked questions

What sensor types does this meter accept?

It accepts both RTD and thermocouple inputs, covering a measurement range of -200°C to 1800°C.

What is the panel cutout size for installation?

The required panel cutout is rectangular, 92.00 mm by 45.00 mm, which matches the standard 1/8 DIN footprint.

What supply voltage does it need?

It operates on 100 to 240 VAC, so it connects directly to line voltage without an external power supply.

MPN
K3MA-L 100-240VAC