Skip to main content
Omron K8AC-H21CN-FLK — Process / Temperature Controllers

Omron K8AC-H21CN-FLK Heater Element Detector

MPNK8AC-H21CN-FLK
Active

Omron K8AC-H series, Heater Element Detector, order code K8AC-H21CN-FLK, input range 0.20 ~ 2.20A, RS-485 communications, DIN rail mount, 85 ~ 264VAC supply.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

K8AC-H21CN-FLK — Identification
ParameterValue
SeriesK8AC-H
TypeHeater Element Detector
K8AC-H21CN-FLK — Electrical
ParameterValue
Supply voltage85 ~ 264VAC
K8AC-H21CN-FLK — Performance
ParameterValue
Control methodOn/Off
FeaturesHeater Fault Detection
K8AC-H21CN-FLK — I/O
ParameterValue
Input range0.20 ~ 2.20A
Output typeSolid State (2)
K8AC-H21CN-FLK — Communication
ParameterValue
Communication interfacesRS-485 (CompoWay/F)
K8AC-H21CN-FLK — Display
ParameterValue
Display typeLED - Red Characters
Characters per row4
K8AC-H21CN-FLK — Environmental
ParameterValue
Operating temperature-10°C ~ 55°C
K8AC-H21CN-FLK — Mechanical
ParameterValue
Mounting typeDIN Rail
Termination styleSpring Terminal
K8AC-H21CN-FLK — Other specifications
ParameterValue
Weight0.441 lb (200.03 g)

Product details

Heater Current Monitor on DIN Rail

The Omron K8AC-H21CN-FLK is a dedicated heater element detector from the K8AC-H series, designed to monitor heater current and signal a fault when the draw falls outside the set range. The input range spans 0.20 ~ 2.20 A, which covers small to moderate heater loads typical in injection molding, packaging seal bars, and process ovens. The two solid-state outputs provide isolated fault signalling to a PLC or alarm annunciator.

RS-485 and Supply Voltage

Communications are handled via RS-485 using the CompoWay/F protocol, so the unit can report heater current values and fault status back to a host controller over a multi-drop network. The supply voltage accepts 85 ~ 264 VAC, covering both 100 V and 200 V class mains without a separate transformer tap. Termination is via spring terminals — no screw tightening, which speeds wiring and holds firm under vibration. The 4-digit red LED display shows the measured current value in real time, readable from a few metres away on the panel door.

Active Production — Sourced per RFQ

Frequently asked questions

What is the input range of K8AC-H21CN-FLK?

The input range is 0.20 ~ 2.20 A. This covers small to moderate heater loads; the detector triggers a fault when the measured current falls outside the set threshold.

Does K8AC-H21CN-FLK have RS-485 communication?

Yes, it communicates via RS-485 using the CompoWay/F protocol, allowing multi-drop reporting of current values and fault status to a host controller.

MPN