Omron K8AC-H22PC-FLK Heater Element Detector, K8AC-H series, input range 2 ~ 22A, relay output, LED display, RS-485 communications, DIN rail mount, spring terminals, 85 ~ 264VAC supply.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

K8AC-H22PC-FLK — Identification
ParameterValue
SeriesK8AC-H
TypeHeater Element Detector
K8AC-H22PC-FLK — Electrical
ParameterValue
Supply voltage85 ~ 264VAC
K8AC-H22PC-FLK — I/O
ParameterValue
Input range2 ~ 22A
Output typeRelay
K8AC-H22PC-FLK — Communication
ParameterValue
Communication interfacesRS-485 (CompoWay/F)
K8AC-H22PC-FLK — Performance
ParameterValue
FeaturesHeater Fault Detection
K8AC-H22PC-FLK — Display
ParameterValue
Display typeLED - Red Characters
Characters per row4
K8AC-H22PC-FLK — Environmental
ParameterValue
Operating temperature-10°C~55°C
K8AC-H22PC-FLK — Mechanical
ParameterValue
Mounting typeDIN Rail
Termination styleSpring Terminal
K8AC-H22PC-FLK — Other specifications
ParameterValue
Weight0.441 lb (200.03 g)

Product details

Active Heater Current Monitor for Panel Integration

The K8AC-H22PC-FLK is an active-production heater element detector from Omron's K8AC-H series, designed to monitor current draw of resistive heater loads and alarm on open-element or partial-fault conditions. Its input range of 2 ~ 22A covers most single- and three-phase heater strings in industrial ovens, packaging seal bars, and injection-molding nozzle heaters — the 4-digit red LED shows live current so a quick glance tells you if a zone dropped out. Mounts on standard DIN rail (35 mm) and terminates via spring-clamp terminals — no screwdriver needed for the field wiring, which matters when you're swapping a failed unit on a live panel and every second counts.

Communications and Supply — What Fits the Van

Built-in RS-485 with Omron's CompoWay/F protocol lets you poll the detector over a two-wire bus from a PLC or HMI — useful when the heater bank is on the far side of the plant and you want the alarm in the SCADA log, not just a local light. Universal AC supply 85 ~ 264 VAC means it runs on anything from a 110 V control transformer to a 240 V line without a jumper change — one part number for the whole panel build. Operating temperature -10°C to 55°C covers most indoor control cabinets; keep it out of direct steam washdown areas despite the DIN-rail form factor.

Sourcing and Lifecycle — No Hunt Required

Sourced and quoted to order against your BOM quantity through independent distribution. Availability and current pricing confirmed at RFQ time — no guesswork on whether the line can be filled.

Frequently asked questions

What is K8AC-H22PC-FLK's input range and what does it detect?

The K8AC-H22PC-FLK monitors heater current from 2 A to 22 A. It detects open heater elements, partial faults, and current deviations in resistive loads — the relay output triggers an alarm when the measured current falls outside the configured thresholds, preventing cold zones in process heating applications.